2009
DOI: 10.1177/230949900901700104
|View full text |Cite
|
Sign up to set email alerts
|

Philos Plate Fixation for Displaced Proximal Humeral Fractures

Abstract: Philos plate fixation provided stable fixation, minimal metal work problems and enabled early range-of-motion exercises to achieve acceptable functional results.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

8
43
1

Year Published

2010
2010
2018
2018

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 57 publications
(52 citation statements)
references
References 30 publications
8
43
1
Order By: Relevance
“…In our study, total of 7 patients out of 32 had complications (21.8%). In literature, the reported complication rates are ranging from 3.7% to 35.7% [9,11,12] The main complication in our study was inadequate reduction of the fracture ( Fig. 1).…”
Section: Discussionmentioning
confidence: 81%
“…In our study, total of 7 patients out of 32 had complications (21.8%). In literature, the reported complication rates are ranging from 3.7% to 35.7% [9,11,12] The main complication in our study was inadequate reduction of the fracture ( Fig. 1).…”
Section: Discussionmentioning
confidence: 81%
“…Keeping in mind the various possible advantage of proximal humerus locking plate. [1,4,8,14,16,29,32,33,37,38,42] In the present study, the average age was lower because a sizeable number of the patients (8 patients) sustained a high energy trauma in road traffic accident. It is pertinent to mention that younger age group is more likely to be outgoing and exposed to road traffic accident as compared to older age group.…”
Section: Section: Orthopaedicsmentioning
confidence: 82%
“…To achieve this goal, a variety of implants of internal fixation have been employed with variable success.Implants can range from percutaneous k-wiring conventional plates such as T plate , [9,36,39,44] blade plate one third tubular plate43,circlage or tension band wiring using a stainless steel wire, [26,38,24] helix wiring, [35] externalfixator, [28,30] intramedullary nail, [14,20,23,24,25,27,41] locking plate, [1,4,8,14,16,29,32,33,37,38,42] to hemiarthoplasty. [19] The best treatment for displaced proximal humerus fracture remains controversial and the discussion about ideal implant for such cases still continues.…”
Section: Section: Orthopaedicsmentioning
confidence: 99%
“…Ramachander Siwach et al [8] treated 12 two part and 13 three part fracture using LCP. MA Fazal et al [6] treated 27 of their cases (13 two part and 12 three part) using PHILOS plating. When compared with other studies present study shows less complications.…”
Section: Methodsmentioning
confidence: 99%