2000
DOI: 10.1080/00032710008543157
|View full text |Cite
|
Sign up to set email alerts
|

Phosphorescent Sensor Approach for Non-Destructive Measurement of Oxygen in Packaged Foods: Optimisation of Disposable Oxygen Sensors and their Characterization Over a Wide Temperature Range

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
30
0

Year Published

2004
2004
2017
2017

Publication Types

Select...
6
3

Relationship

2
7

Authors

Journals

citations
Cited by 55 publications
(31 citation statements)
references
References 22 publications
0
30
0
Order By: Relevance
“…Oxygen permeability was measured under controlled condition (50 ± 3% relative humidity, 23 ± 2°C) according to the method developed by Papkovsky et al (2000). The films were mounted between the upper lid and rubber ring with silicon lubricant and fixed to the lower cup by screws, with an oxygen sensor housed inside.…”
Section: Film Oxygen Permeabilitymentioning
confidence: 99%
“…Oxygen permeability was measured under controlled condition (50 ± 3% relative humidity, 23 ± 2°C) according to the method developed by Papkovsky et al (2000). The films were mounted between the upper lid and rubber ring with silicon lubricant and fixed to the lower cup by screws, with an oxygen sensor housed inside.…”
Section: Film Oxygen Permeabilitymentioning
confidence: 99%
“…There is also a possibility to incorporate them into packaging materials. Their good sensitivity (0.02% of oxygen), dynamic range (0-100%) and the absence of cross sensitivity to other species (Papkovsky et al, 1995;Papkovsky et al, 2000), makes them suitable for a wide range of products.…”
Section: Discussionmentioning
confidence: 98%
“…Since the concept was first introduced (Fitzgerald, Papkovsky, OÕSul-livan, & Guilbault, 1998;Reininger, Kolle, Trettnak, & Gruber, 1996), considerable advancements have been made in the development of fluorescence-based oxygen sensors for packaging applications (Demas, DeGraff, & Coleman, 1999;Fitzgerald et al, 2001;Papkovsky, Papkovskaia, Smyth, Kerry, & Ogurtosov, 2000;Saini & Desault, 2002). In particular, our research team have developed a non-invasive, non-chemical and completely reversible system, which operates via a small plastic sensor elements incorporated in each pack and an external device-fluorescence phase detector.…”
Section: Introductionmentioning
confidence: 97%
“…Oxygen permeability was measured according to the method developed by Papkovsky et al (2000) and Wang et al (2007) under controlled condition (50 ± 5% RH and 23 ± 2°C). Prior to analysis, an oxygen sensor was placed inside the test chamber.…”
Section: Oxygen Permeability (Op)mentioning
confidence: 99%