1999
DOI: 10.1016/s0955-2219(99)00015-1
|View full text |Cite
|
Sign up to set email alerts
|

Photoacoustic thermal characterization of electrical porcelains: effect of alumina additions on thermal diffusivity and elastic constants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0
4

Year Published

2006
2006
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 18 publications
0
6
0
4
Order By: Relevance
“…The measured signal is dependent on the frequency response of the detection apparatus. Thus, a calibration or normalization function is necessary to obtain a PA signal that depends only on the sample [17,30,31,36,37]. The measured signal S can be expressed as follows [17,38,39]:…”
Section: Calibrationmentioning
confidence: 99%
See 2 more Smart Citations
“…The measured signal is dependent on the frequency response of the detection apparatus. Thus, a calibration or normalization function is necessary to obtain a PA signal that depends only on the sample [17,30,31,36,37]. The measured signal S can be expressed as follows [17,38,39]:…”
Section: Calibrationmentioning
confidence: 99%
“…where ω c1 = 2πf c1 is the cut-off frequencies of the microphone electronics, ω c2 = 2πf c2 is the cut-off frequencies of the signal processing electronics, ω c3 = 2πf c3 is the microphone cut-off frequency, ω c4 = 2πf c4 is the microphone geometric characteristic frequency, δ c3 and δ c4 are the damping factor. In most cases, aluminum foil of thickness 10 µm is used as a reference sample [35,36] with aluminum's thermal diffusivity of 86 × 10 −6 m 2 s −1 and all other necessary physical properties being well known [15]. The TE effect is typically considered negligible in δP real when compared to the TD contribution for thin samples, and the calibration is performed by the approximation of the thermally thin regime in thermal diffusion.…”
Section: Calibrationmentioning
confidence: 99%
See 1 more Smart Citation
“…Here, an open photoacoustic cell (OPC) in the transmission configuration (Vargas & Miranda, 1988, Bribiesca et al, 1999) is employed to evaluate thermal diffusivity and the photothermal technique of continuous investigation illumination on the sample in a vacuum (Contreras et al, 1997) is used to measure thermal capacity density.…”
Section: Wwwintechopencommentioning
confidence: 99%
“…A Fig. 2 mostra a dependência do sinal fotoacústico com a freqüência de modulação para uma amostra de alumínio [22,23].…”
Section: Medidas De Difusividade Térmicaunclassified