2022
DOI: 10.14233/ajchem.2022.23578
|View full text |Cite
|
Sign up to set email alerts
|

Photocatalytic Degradation of Rhodamine B Dye by Using Tin-Doped CeO2-Fe2O3 Nanocomposite

Abstract: Organic dyes are frequently used in various industries such as textiles, medicines, plastics, etc. and contribute as a major source of environmental pollutants, which leads to harmful effects on livings. Therefore, in this study, a Sn-doped CeO2-Fe2O3 photocatalyst was synthesized using the thermal decomposition method and applied for the effective degradation and removal of rhodamine B dye under solar irradiation. The as-synthesized catalyst was characterized by powder X-ray diffraction (XRD), field-emission … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 52 publications
0
3
0
Order By: Relevance
“…The DFT calculations were performed to develop the lowest energy structures of the ligands (QL1 and QL2) and the metal complexes of the ligands with Cu 2+ ions (Fig. 3a-b) [37,38]. The difference in the energy-gap between the homo and lumo orbitals was found 4.45 eV and 4.21 eV, respectively, for QL1 and QL2.…”
Section: Resultsmentioning
confidence: 99%
“…The DFT calculations were performed to develop the lowest energy structures of the ligands (QL1 and QL2) and the metal complexes of the ligands with Cu 2+ ions (Fig. 3a-b) [37,38]. The difference in the energy-gap between the homo and lumo orbitals was found 4.45 eV and 4.21 eV, respectively, for QL1 and QL2.…”
Section: Resultsmentioning
confidence: 99%
“…Validation: The current method was validated for accuracy, robustness, linearity and precision as described in ICH regulations [35]. The diastereomeric pair (P5 and P6) of propranolol prepared with QCR3 was used as a representative to validate the developed method as described in the literature [15,21,34,35]. The concentration of the samples was used in the range of 60-6000 ng/mL and the detection limit (LOD), quantification limit (LOQ), linearity, accuracy, precision and relative standard deviation (RSD) were calculated.…”
Section: Resultsmentioning
confidence: 99%
“…The validation of the current analytical method was performed as per ICH regulations [30]. The validation study was conducted on diastereomers prepared with QCR-6 (DF-1 and DF-2) as a representative, as described in literature [8,9,31]. The concentration range of 30-3000 ng/mL was used for the validation and the detection limit (LOD), the quantification limit (LOQ), linearity, accuracy, precision and relative standard deviation (RSD) were determined.…”
Section: Validationmentioning
confidence: 99%