1986
DOI: 10.1063/1.450608
|View full text |Cite
|
Sign up to set email alerts
|

Photoelectron spectroscopy of the negative ion SeO−

Abstract: We have recorded the photoelectron spectrum of SeO− using a newly constructed negative ion photoelectron spectrometer. The adiabatic electron affinity of SeO is determined to be 1.456±0.020 eV. Values of ν00(a 1Δ–X 3Σ−0+) and ΔG1/2(a 1Δ) are found to be 5530±200 and 916±35 cm−1, respectively, in substantial accord with previous measurements. The negative ion parameters determined in this work are: B″e(SeO−) =0.4246±0.0050 cm−1 which leads to  r′e(SeO−)=1.726±0.010 Å, ω″e(SeO−)=730±25 cm−1, ω′e x″e(SeO−)=2±4 cm… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
54
0

Year Published

1986
1986
2016
2016

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 94 publications
(56 citation statements)
references
References 32 publications
2
54
0
Order By: Relevance
“…In one case, they were produced with a nozzle-ion source and their photoelectron spectra measured with a continuous anion photoelectron apparatus. 45 In the other case, the anions were generated with a photoinduced electron emission source, and their photoelectron spectra were measured with a pulsed anion photoelectron apparatus. 46 In both instruments, anion photoelectron spectroscopy was conducted by crossing a mass-selected beam of negative ions with a fixed-frequency photon beam and then energy analyzing the resultant photodetached electrons.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In one case, they were produced with a nozzle-ion source and their photoelectron spectra measured with a continuous anion photoelectron apparatus. 45 In the other case, the anions were generated with a photoinduced electron emission source, and their photoelectron spectra were measured with a pulsed anion photoelectron apparatus. 46 In both instruments, anion photoelectron spectroscopy was conducted by crossing a mass-selected beam of negative ions with a fixed-frequency photon beam and then energy analyzing the resultant photodetached electrons.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…In this type of anion photoelectron spectrometer, the ion source and all of the other components operate continuously. 45 The ion source was a biased (−500 V), supersonic expansion nozzle-ion source in which the acetoacetic acid sample was placed inside its stagnation chamber. There, due to the warming of the source by the adjacent hot filament, some of the sample evaporated and was expanded through a 25 μm diameter nozzle orifice into ∼10 −4 Torr vacuum along with argon gas which was maintained at a pressure of 1−2 atm in the source's stagnation chamber.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…All photoelectron spectra reported here were recorded with 2.540 eV photons and calibrated against the photoelectron spectrum of O − [15,16]. Our apparatus has been described previously [17].…”
Section: Experimental and Computational Methodsmentioning
confidence: 99%
“…Our negative ion photoelectron spectrometer has been described elsewhere. 30 Anions were formed in our supersonic expansion source. There, the mixture of indole and water was heated to approximately 70…”
Section: Methodsmentioning
confidence: 99%