1956
DOI: 10.1021/ac60111a032
|View full text |Cite
|
Sign up to set email alerts
|

Photometric Determination of Boron in Titanium and its Alloys

Abstract: Dehydroascorbic acid, p-benzoquinone, anthraquinone disulfonie acid, and chloranil gave strong responses. The fact that vitamin K3 catalyzes the reaction makes it probable that vitamins Ki and K3, which also contain a naphthaquinone nucleus, would function in this manner.Sodium dehydrotartrate showed no catalytic effect despite the fact that it is a 1,2-diketone.The sensitive detectability of 1,2-diketones and quiñones, through their catalytic activity in the formaldehyde-1,2dinitrobenzene system, makes possib… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

1957
1957
1980
1980

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 6 publications
0
4
0
Order By: Relevance
“…Presence of the complex makes the end point determination of the subsequent water titration uncertain. Because excess peroxide will interfere with the wrater titration, both the peroxide and titanium-peroxide complex are destroyed by prolonged heating with a ferrous catalyst (2).…”
Section: Discussionmentioning
confidence: 99%
“…Presence of the complex makes the end point determination of the subsequent water titration uncertain. Because excess peroxide will interfere with the wrater titration, both the peroxide and titanium-peroxide complex are destroyed by prolonged heating with a ferrous catalyst (2).…”
Section: Discussionmentioning
confidence: 99%
“…Absorptivity stated in numerical terms in reference cited. 4 Absorptivity estimated from calibration or absorbance curves in reference cited. " Data obtained on filter photometer; all other data obtained on spectrophotometers.…”
Section: Hydroxyanthraquinone and Anthraquinonylamine Reagentsmentioning
confidence: 99%
“…The fuel and average irradiation time of 120 minutes are the same for all runs except run 1-11, in which the fuel was changed. The concentration values given are the peak concentrations obtained after irradiations of 3 to 4 hours.…”
mentioning
confidence: 99%
“…In determining magnesium with titan yellow, the interference caused by manganese-(II), copper(II), iron(III), and aluminum can be prevented by adding potassium cyanide and hydroxylamine (78).…”
Section: Arsenazo-[o-mentioning
confidence: 99%