2018
DOI: 10.3847/1538-4357/aac330
|View full text |Cite
|
Sign up to set email alerts
|

Photon Flux and Bunching Noise from Measurement of the Shot Noise Variance

Abstract: We report the experimental observation of photon bunching noise through shot noise measurements made on a pseudo-thermal state of light using balanced detection. A full theory describing the measurement is developed, and in agreement with theory it is found that the shot noise variance in the balanced signal reproduces the time series of the flux of the primary incoherent beam. Moreover, when the average power of the pseudo-thermal light is varied, the balanced detection is seen to track this change. A compari… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 12 publications
0
2
0
Order By: Relevance
“…electronic noise was generated following a Poisson distribution with a variance of 209 electrons (i.e., 5238×2×2×Ofalse(102false)$5238 \times 2 \times 2 \times O(10^{-2})$); charge collection coefficient (i.e., conversion rate of optical photons to e‐h pairs by the photodiode) of 1 was used during this implementation. To reduce the effect of electronic noise, the mean value of the added electronic noise was calibrated to zero 44–48 . The Hanning‐weighted ramp filter was then applied to the projection data 49 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…electronic noise was generated following a Poisson distribution with a variance of 209 electrons (i.e., 5238×2×2×Ofalse(102false)$5238 \times 2 \times 2 \times O(10^{-2})$); charge collection coefficient (i.e., conversion rate of optical photons to e‐h pairs by the photodiode) of 1 was used during this implementation. To reduce the effect of electronic noise, the mean value of the added electronic noise was calibrated to zero 44–48 . The Hanning‐weighted ramp filter was then applied to the projection data 49 .…”
Section: Methodsmentioning
confidence: 99%
“…To reduce the effect of electronic noise, the mean value of the added electronic noise was calibrated to zero. [44][45][46][47][48] The Hanning-weighted ramp filter was then applied to the projection data. 49 The filtered projection data were voxel-driven backprojected with linear interpolation to reconstruct a breast tomosynthesis volume of size 64×64×16 (i.e., 6.4×6.4×6.4 mm 3 ).Note that the reconstructed voxel size was 0.1×0.1×0.4 mm 3 in our work, thus resulting in a slice thickness of 0.4 mm.…”
Section: Image Generationmentioning
confidence: 99%