2016
DOI: 10.1167/tvst.tvst.5.4.8
|View full text |Cite
|
Sign up to set email alerts
|

Photopic Negative Response Obtained Using a Handheld Electroretinogram Device: Determining the Optimal Measure and Repeatability

Abstract: The PhNR can be measured for clinical and research purposes using a simple-to-implement technique that is consistent within and between visits, and also between examiners.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
11
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(12 citation statements)
references
References 14 publications
1
11
0
Order By: Relevance
“…The components of the RETeval system have been described in detail. [16][17][18][19][20][21][22][23] In brief, full-field stimuli are presented with a 60-mm diameter dome, and the white stimuli are created by a combination of three colored light emitting diodes. The frequency of the flicker stimulus was 28.306 Hz, and the pulse duration was less than 1 msec.…”
Section: Flicker Erg Recordings By Retevalmentioning
confidence: 99%
See 1 more Smart Citation
“…The components of the RETeval system have been described in detail. [16][17][18][19][20][21][22][23] In brief, full-field stimuli are presented with a 60-mm diameter dome, and the white stimuli are created by a combination of three colored light emitting diodes. The frequency of the flicker stimulus was 28.306 Hz, and the pulse duration was less than 1 msec.…”
Section: Flicker Erg Recordings By Retevalmentioning
confidence: 99%
“…A full-field flicker ERG recording system called the RETeval system was recently developed. [16][17][18][19][20][21] This system is comprised of a small, hand-held Ganzfeld dome used with a special single-use, skin electrode array. This system can record flicker ERGs without mydriasis because the device delivers stimulus flashes with constant retinal illuminance (Td-s) by adjusting the luminance (cd-s/m 2 ) to compensate for changes in the pupillary area (mm 2 ) in real time.…”
mentioning
confidence: 99%
“…On a practical level, the presence of PhNR alterations in most Stargardt patients shows that the PhNR is a very sensitive disease read‐out, outperforming other full‐field ERG parameters. Considering the ease with which full‐field ERGs can be recorded in normal ophthalmological practice, including the evaluation of the PhNR in the standard ERG tests could be an almost effortless addition of significant consequence in Stargardt diagnosis and follow‐up.…”
Section: Discussionmentioning
confidence: 99%
“…However, the PhNR can be measured in several different ways, either as the negative trough following the b-wave or at a xed time point [7][8][9]. Wu et al recently reported that the PhNR to B-wave ratio (PhNR/B; B-wave amplitude de ned as the a-wave trough to bwave peak) exhibited the lowest magnitude of test-retest variability and concluded that PhNR/B was the optimal measure of the PhNR [10].…”
Section: Introductionmentioning
confidence: 99%