2007
DOI: 10.1007/s10103-007-0487-1
|View full text |Cite
|
Sign up to set email alerts
|

Photopolymerization of dental resin as restorative material using an argon laser

Abstract: The effect of the 488-nm wavelength of argon laser at different power densities and irradiation times on the degree of conversion (DC), temperature rise, water sorption, solubility, flexural strength, flexural modulus, and microhardness of bisphenole A glycol dimethacrylate and triethylen glycol dimethacrylate with a mass ratio of 75:25 was studied. Camphorquinone and N,N'-dimethyl aminoethyl methacrylate were added to the monomer as a photo initiator system. The DC% of the resin was measured using Fourier tra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 24 publications
0
10
0
Order By: Relevance
“…Indeed, metal complexes are highly controversed photoinitiators/photosensitizers due to their potential toxicities and the resulting photopolymers can't be used for food packaging [290][291] or medical applications. [292][293][294][295][296][297][298][299][300][301] Recently, a great deal of efforts has been devoted to develop biosourced or bioinspired photoinitiating systems. The recent development of chalcones-based photosensitizers corresponds to this new interest, and ferrocene is also well-known to exhibit a low toxicity.…”
Section: Free Radical Polymerization Using Ferrocene-based Chalconesmentioning
confidence: 99%
“…Indeed, metal complexes are highly controversed photoinitiators/photosensitizers due to their potential toxicities and the resulting photopolymers can't be used for food packaging [290][291] or medical applications. [292][293][294][295][296][297][298][299][300][301] Recently, a great deal of efforts has been devoted to develop biosourced or bioinspired photoinitiating systems. The recent development of chalcones-based photosensitizers corresponds to this new interest, and ferrocene is also well-known to exhibit a low toxicity.…”
Section: Free Radical Polymerization Using Ferrocene-based Chalconesmentioning
confidence: 99%
“…The argon ion laser has arisen as an alternative light source for polymerizing resin composites, resin luting cements, and for bleaching procedures [19][20][21]. For camphorquinone-based resins, the activation emits a blue light in the wavelength range 400-500 nm with peak values at about 468 and 480 nm, depending on the monomer formulation, and it has an irradiance at up to 2,000 mW/cm 2 [21][22][23][24].…”
Section: Introductionmentioning
confidence: 99%
“…However, with most current products, filler particle sizes have become much smaller (<1 pm), and the microhardness values appear more reliable [62].…”
Section: Knoop Hardnessmentioning
confidence: 99%
“…Thermal changes are also cyclic in nature, and although the entire restoration may never reach thermal equilibrium during the application of either hot or cold stimuli, the cyclic effect can lead to material fatigue and early bond failure. If a gap were formed, the difference between the thermal coefficient of expansion of composites and teeth could allow for the percolation of oral fluids [62]. …”
Section: Thermal Propertiesmentioning
confidence: 99%