1997
DOI: 10.1023/a:1022183423630
|View full text |Cite
|
Sign up to set email alerts
|

Photosynthetic capacity and specific leaf mass in twenty woody species of Cerrado vegetation under field conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
40
0
5

Year Published

1997
1997
2019
2019

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 129 publications
(45 citation statements)
references
References 12 publications
0
40
0
5
Order By: Relevance
“…Some studies carried out in Brasília showed a significant drop in soil water potential (Ψs) only during the months free from rainfall (usually between July and September) when Ψs values reached -1.5 MPa in layers above 0.85 m (Franco et al, 1996;Franco, 1998;Franco, 2002). The atmosphere CO 2 concentration and air temperature mean values were similar between seasons (table 2), and averages of PPFD values were same or higher than that necessary to saturate net photosynthesis of 20 woody stricto sensu cerrado species studied by Prado and Moraes (1997). Atmosphere vapor pressure deficit (VPD) was 80% higher in the dry season (1.8 kPa) compared to that in the wet season (1.0 kPa), potentially increasing the transpiration under winter drought.…”
Section: Resultsmentioning
confidence: 84%
“…Some studies carried out in Brasília showed a significant drop in soil water potential (Ψs) only during the months free from rainfall (usually between July and September) when Ψs values reached -1.5 MPa in layers above 0.85 m (Franco et al, 1996;Franco, 1998;Franco, 2002). The atmosphere CO 2 concentration and air temperature mean values were similar between seasons (table 2), and averages of PPFD values were same or higher than that necessary to saturate net photosynthesis of 20 woody stricto sensu cerrado species studied by Prado and Moraes (1997). Atmosphere vapor pressure deficit (VPD) was 80% higher in the dry season (1.8 kPa) compared to that in the wet season (1.0 kPa), potentially increasing the transpiration under winter drought.…”
Section: Resultsmentioning
confidence: 84%
“…The A-PPFD curves were estimated using the following PPFD values: 0, 25, 50, 100, 200, 400, 600, 800, 1000, 1200, 1400, 1600, 1800 and 2000 mol photons m -2 s -1 for each gas exchange measurement with an IRGA. The A-PPFD curves were adjusted according to PRADO & MORAES (1997). We calculated several parameters from the curve adjustment: Apparent Quantum Efficiency (AQE), Light saturation Point (Psat), Light compensation Point (Pcom), Dark respiration (Rd), and the Maximum CO2 Assimilation (Amax).…”
Section: Methodsmentioning
confidence: 99%
“…Data was tested for normality of the distribution of residues, variance homogeneity and submitted to ANOVA followed by regression analysis at 5% error probability. For A as a function of PPFD, we used equation proposed by Prado and Moraes (1997) while other variables had their models adjusted by significant equations, based on the highest coefficient of determination. The apparent quantum efficiency and light compensation point was submitted by Tukey test at 5% error probability.…”
Section: Methodsmentioning
confidence: 99%