2017
DOI: 10.1016/j.jphotochem.2017.08.063
|View full text |Cite
|
Sign up to set email alerts
|

Phototransformation of cyanine dye with two chromophores. Effects of oxygen and dye concentration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 29 publications
0
5
0
1
Order By: Relevance
“…Therefore, the relative singlet oxygen quantum yield of the prepared FSNPs was evaluated indirectly by using a commercially available 1 O 2 indicator 1,3-diphenylisobenzofuran (DPBF) as a chemical trap . Distinctly, FSNP-A–C had a higher relative singlet oxygen quantum yield (Table S3) compared to the corresponding FSNP-a–c and free dye a–c (Φ MB = 0.52 as a reference), , while ICG or IR-787 had a value of only 0.008 or 0.007 . According to comparative tests for FSNP-C (Figure S8), the absorbance of DPBF decreased remarkably in the presence of FSNP-C under irradiation, giving the highest relative singlet oxygen quantum yield of Φ Δ = 0.085.…”
Section: Results and Discussionmentioning
confidence: 99%
“…Therefore, the relative singlet oxygen quantum yield of the prepared FSNPs was evaluated indirectly by using a commercially available 1 O 2 indicator 1,3-diphenylisobenzofuran (DPBF) as a chemical trap . Distinctly, FSNP-A–C had a higher relative singlet oxygen quantum yield (Table S3) compared to the corresponding FSNP-a–c and free dye a–c (Φ MB = 0.52 as a reference), , while ICG or IR-787 had a value of only 0.008 or 0.007 . According to comparative tests for FSNP-C (Figure S8), the absorbance of DPBF decreased remarkably in the presence of FSNP-C under irradiation, giving the highest relative singlet oxygen quantum yield of Φ Δ = 0.085.…”
Section: Results and Discussionmentioning
confidence: 99%
“…To determine its ability to generate 1 O 2 , the indirect method for determination of 1 O 2 quantum yield, employing uric acid (UA) as the 1 O 2 sensor is used, which has proven to be a reliable, accurate, and low-cost method. ,, By this method, the solution containing the vesicle system and UA was irradiated at 450 nm, which is the maximum absorption wavelength of the system, and electronic absorption spectra were recorded in intervals from 0 to 1320 s (Figure A). As control measurements, spectra were also recorded in similar experiments containing the Phe–Phe structure (Figure B); C6 (Figure C); perillyl alcohol (Figure D); a combination of C6 and perillyl alcohol (Figure E); and a combination of C6 and Phe–Phe structure (Figure F).…”
Section: Resultsmentioning
confidence: 99%
“…In the pro-oxidant activity assessment, UA was used as the O 2 1 sensor. , UA was dissolved in 2 mL of 1:1 of ethanol and water mixture to result in an absorbance between 1.0 and 1.8. Phe–Phe vesicles were dispersed in 2 mL of UA solution of UA and in a quartz cuvette.…”
Section: Materials and Methodologymentioning
confidence: 99%
See 1 more Smart Citation
“…Uma forma de mimetizar a membrana celular é utilizar micelas de diversos tipos de surfactantes. Tal método vem sendo usado há bastante tempo com diversos resultados importantes no campo da interação entre FS e micelas com diferentes características [37][38][39][40].…”
Section: Introductionunclassified