2019
DOI: 10.3390/en12193774
|View full text |Cite
|
Sign up to set email alerts
|

Photovoltaic Energy Yield Improvement in Two-Stage Solar Microinverters

Abstract: The focus in this paper is on the two-stage photovoltaic (PV) microinverters using a buck-boost dc/dc front-end converter. Wide input voltage range of the front-end converter enables operation under shaded conditions but results in mediocre performance in the typical voltage range. These microinverters can be controlled with either fixed or variable dc-link voltage control methods. The latter improves the converter efficiency considerably in the range of the most probable maximum power point (MPP) locations. H… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 27 publications
0
4
0
Order By: Relevance
“…As the cell exposed to the shadow acts as a heating resistor during shielding, the current flowing through it generates additional (Jolule) heat. The contaminant blocks the emission of this heat; therefore, the cell overheats [7,8]. Local overheating can cause the cells to burn out, affecting the operation of the entire solar panel.…”
Section: Forms Of Deposits On the Surface Of The Solar Cellmentioning
confidence: 99%
“…As the cell exposed to the shadow acts as a heating resistor during shielding, the current flowing through it generates additional (Jolule) heat. The contaminant blocks the emission of this heat; therefore, the cell overheats [7,8]. Local overheating can cause the cells to burn out, affecting the operation of the entire solar panel.…”
Section: Forms Of Deposits On the Surface Of The Solar Cellmentioning
confidence: 99%
“…The entire configuration of the investigated system is shown in Fig. 1, while the parameters of the PV module based on Jinko Solar JKM300M-60B are adopted from the work [14]. The PV module operates at the maximum power point (MPP) by adopting the perturb and observe (P&O) technique due to its simplicity.…”
Section: Description Of the Studied Systemmentioning
confidence: 99%
“…The FIDES guidelines are only relevant to ambient temperatures ranging from -55 o C to 125 o C, which is aligned with our mission profile. The general expression for an item failure rate can be given as λ = Π PM Π Process λ Phy (14) where Π PM is the quality and technical control over manufacturing of the item, Π Process comprises all the steps of item processes from specification to field operation and maintenance, and λ Phy is the physical failure rate of the item, which can be calculated in the mission profile phase as…”
Section: B Approach Based On Fides Guidementioning
confidence: 99%
“…For micro-converters, which are of interest to this work, [11] estimated that they can increase the yearly energy yield of a PV system up to 6%, recovering, on average, 36% of the power otherwise lost from partial shading. Other works have investigated the energy production improvement of PV power systems based on micro-inverters, with [12] finding that a twostage solar micro-inverter increased energy production close to 2% in one day, resulting in a reduction in annual energy losses between 22.3% and 26%. A highly efficient micro-inverter topology using LLC resonant converter is studied in [13]; however, dedicated studies are required to assess its energy recovery potential over time.…”
Section: Introductionmentioning
confidence: 99%