Abstract: Physical and dosimetric characteristics of HDMLC were studied for SRS6, 6, and 10 MV X‐rays from Novalis Tx. This in‐built tertiary collimator consists of 60 pairs (32×0.25 cm; 26×0.5 cm and 2×0.7 cm) of leaves. Properties of HDMLC studied included alignment, readout and radiation field congruence, radiation penumbra, accuracy and reproducibility of leaf position and gap width, static and dynamic leaf shift, tongue‐and‐groove effect, leaf transmission and leakage, leaf travel speed, and delivery of dynamic con… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
25
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(25 citation statements)
references
References 32 publications
0
25
0
Order By: Relevance
“…Other MLCs have been reported to achieve comparable accuracy. 17,19 Second, AQA and robot pointing tests with MLC did not show any deterioration over the test cycle and yielded similar numerical data as for fixed cone assemblies. 23,24 This demonstrates that the mechanical stability of the robotic arm is adequate to handle the higher weight of the MLC (48 kg compared to 30 kg for fixed cones/35 kg for Iris) in routine use.…”
Section: Discussionmentioning
confidence: 58%
See 3 more Smart Citations
“…Other MLCs have been reported to achieve comparable accuracy. 17,19 Second, AQA and robot pointing tests with MLC did not show any deterioration over the test cycle and yielded similar numerical data as for fixed cone assemblies. 23,24 This demonstrates that the mechanical stability of the robotic arm is adequate to handle the higher weight of the MLC (48 kg compared to 30 kg for fixed cones/35 kg for Iris) in routine use.…”
Section: Discussionmentioning
confidence: 58%
“…However, its specific design and leaf tilt caused slight differences between Y + and Y − penumbrae as well as a dependence on off-axis position, which were not seen with other MLCs. 19,21 Transmission and leakage of the InCise™ MLC did not exceed 0.5% for any assessed Linac head orientation. This result compares favorably to several other current MLCs with small leaf width, which yielded larger values of around 1% or higher.…”
Section: Discussionmentioning
confidence: 88%
See 2 more Smart Citations
“…The detailed physical and dosimetric characteristics of HDMLC especially for radiosurgery and IMRT were reported elsewhere. [22] In comparison to other mMLC/MLC, HDMLC has thinner leaf width, less effective penumbra and leakage. A margin dose of 12-13 Gy (mean 12.3 Gy) was prescribed at 80% isodose while maintaining the maximum dose to brainstem at 12 Gy and minimizing the dose to cochlea as low as possible.…”
Section: Methodsmentioning
confidence: 99%