Physical Characteristics of the Radiations From 2-Pulse, 12-Pulse, and 1,000-Pulse X-Ray Equipment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

1982
1982
2014
2014

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…ultrasonography). Many methods have also been developed for the estimation of conceptus dose from several radio-diagnostic examinations [5,6,7,8,9,10,11,12]; however, a detailed dose assessment is not always needed. Thus, the dose received by the conceptus during the first 2 weeks post-conception will either terminate the pregnancy, or the conceptus will recover completely.…”
Section: Anticipation Of Conceptus Dose and Riskmentioning
confidence: 99%
See 1 more Smart Citation
“…ultrasonography). Many methods have also been developed for the estimation of conceptus dose from several radio-diagnostic examinations [5,6,7,8,9,10,11,12]; however, a detailed dose assessment is not always needed. Thus, the dose received by the conceptus during the first 2 weeks post-conception will either terminate the pregnancy, or the conceptus will recover completely.…”
Section: Anticipation Of Conceptus Dose and Riskmentioning
confidence: 99%
“…There is no allowance for beamquality variations; data apply to specific kVp-half value layer (HVL) combinations. Harrison [6] and Kelley and Trout [9] measured the relative percentage of dose as a function of depth. Schulz and Gignac [10] provided tables with tissue-air ratios to convert free-in-air exposure to depth dose.…”
Section: Anticipation Of Conceptus Dose and Riskmentioning
confidence: 99%
“…The high voltage generator consists of an inverter for high voltage generation, a high frequency transmitter, a high pressure transformer, a rectifier for supplying direct current with high pressure, an X-ray tube filament heating circuit, and a transmitter for generating electron. The inverter used generates a high-voltage waveform with low ripples, and makes switching frequency higher from a general power supply, which leads to a high exposure dose of X-ray per unit hour [10][11][12]. In this study, X-ray tube was used DF-151BS device which is made by Toshiba and it was able to generate 3.3 kW level of output.…”
Section: X-ray Generatormentioning
confidence: 99%
“…This entrance exposure is then used to calculate the dose at the depth of the fetus by using either published depth-dose (23)(24)(25) or tissue-air ratio tables (26,27). This procedure is applicable to both radiographic and fluoroscopic exposures.…”
Section: Direct (Inside Field Of View) Exposure-mentioning
confidence: 99%