“…The dose was slowly injected into the right antecubital vein in a dimly lit and quiet room. Serial SPECT scans (5 min, 6 h and 24 h) were performed on a dedicated Siemens MultiSPECT 3 gamma camera with fan-beam collimators (Siemens Medical Systems; Hoffman Estates I11., USA) [11]. Head positioning was monitored during acquisition by using two position lasers.…”
Section: Methodsmentioning
confidence: 99%
“…The SPECT scans were decay-corrected and reconstructed with Butterworth-filtered back-projection in a 128 × 128 matrix with a pixel size of 3 × 3 mm, and were attenuation-corrected with Chang's algorithm [10,11]. The imaging resolution was 8–9 mm.…”
Background: Results obtained from brain imaging studies indicate that serotonin transporter (SERT) and dopamine transporter (DAT) densities are altered in major depression. However, no such studies have been published on current mania or hypomania.
“…The dose was slowly injected into the right antecubital vein in a dimly lit and quiet room. Serial SPECT scans (5 min, 6 h and 24 h) were performed on a dedicated Siemens MultiSPECT 3 gamma camera with fan-beam collimators (Siemens Medical Systems; Hoffman Estates I11., USA) [11]. Head positioning was monitored during acquisition by using two position lasers.…”
Section: Methodsmentioning
confidence: 99%
“…The SPECT scans were decay-corrected and reconstructed with Butterworth-filtered back-projection in a 128 × 128 matrix with a pixel size of 3 × 3 mm, and were attenuation-corrected with Chang's algorithm [10,11]. The imaging resolution was 8–9 mm.…”
Background: Results obtained from brain imaging studies indicate that serotonin transporter (SERT) and dopamine transporter (DAT) densities are altered in major depression. However, no such studies have been published on current mania or hypomania.
“…This patient's global and segmental left ventricular function was normal and he had a slight elevation of troponin I level (<10 ng/ml). The most likely explanation for these findings is that the myocardial area at risk was small, since the spatial resolution of tomographic scintigraphy in devices as the one used in our study is approximately 10x10x10mm 19 . Some imaging studies have shown that approximately 13% of the subendocardial infarctions with normal ECG are detected by magnetic resonance, but they are below the resolution cutoff value of the gamma camera 20 .…”
“…Immediate planar imaging was performed using a dual head gamma camera (e.cam, Siemens Healthcare, Munich Germany) using a low energy highresolution collimator with 9.1mm resolution [32]. Dynamic images were taken in the anterior or oblique view (20 x 60s, 128 x128 matrix).…”
Section: Outpatient Nuclear Medicine Imagingmentioning
These data show a surgeon naïve to the results of traditional pre-operative sentinel node imaging can use fhSPECT in the operating theatre to accurately locate sentinel nodes in oral cancer. Freehand SPECT showed excellent sensitivity and a low false negative rate offering the possibility of a streamlined intraoperative sentinel node protocol.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.