2007
DOI: 10.1109/tns.2006.890323
|View full text |Cite
|
Sign up to set email alerts
|

Physics Performance of the Barrel RPC System of the HARP Experiment

Abstract: Index Terms-Gaseous detector, HARP, particle identification, resistive plate chamber (RPC), time-of-flight (TOF).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
34
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(37 citation statements)
references
References 6 publications
3
34
0
Order By: Relevance
“…[4] and [5], and summarized succinctly in the appendix of Ref. [1], our calibrations disagree with those published by the 'HARP Collaboration' [6][7][8][9]. Conclusions of independent review bodies on the discrepancies between our results and those from the HARP Collaboration can be found in Refs.…”
Section: Introductionmentioning
confidence: 49%
“…[4] and [5], and summarized succinctly in the appendix of Ref. [1], our calibrations disagree with those published by the 'HARP Collaboration' [6][7][8][9]. Conclusions of independent review bodies on the discrepancies between our results and those from the HARP Collaboration can be found in Refs.…”
Section: Introductionmentioning
confidence: 49%
“…This resolution represents the convolution with the non-negligible dE/ dx resolution, but is hardly compatible with the claimed 6 0.3 (GeV/c) −1 . Incidentally, convincing confirmation that the momentum resolution is much worse than claimed is given in [4] and [5]. Therein, the RPC time-of-flight resolution of p ∼ 200 MeV/c pions that is equivalent to the momentum resolution in the TPC is quoted as 260 ps.…”
Section: On the Momentum Resolutionmentioning
confidence: 90%
“…17 (upper left panel) where they show the measurement of the specific ionization dE/dx of protons as a function of momentum 4 . One only needs to overlay the theoretical prediction, well visible in the three other panels, on the proton entries.…”
Section: On the Momentum Scalementioning
confidence: 99%
See 1 more Smart Citation
“…[5] and [6]. Therein, the RPC time-of-flight resolution of p ∼ 200 MeV/c pions that is equivalent to the p T -3 - resolution in the TPC is quoted as 260 ps.…”
Section: Harp's Biased P T Scale and Bad P T Resolutionmentioning
confidence: 99%