2011
DOI: 10.1016/j.snb.2010.10.006
|View full text |Cite
|
Sign up to set email alerts
|

Piezoelectric cantilever sensors with asymmetric anchor exhibit picogram sensitivity in liquids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
35
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
7
1
1

Relationship

3
6

Authors

Journals

citations
Cited by 41 publications
(37 citation statements)
references
References 29 publications
2
35
0
Order By: Relevance
“…13 in Table I. 15,21 The correlation of sensor response with liquid density (Fig. Responses of both bending and torsional modes in PEMC were larger than the longitudinal mode based on frequency shift, while Q-value persistence in high viscosity liquids was comparable.…”
mentioning
confidence: 97%
“…13 in Table I. 15,21 The correlation of sensor response with liquid density (Fig. Responses of both bending and torsional modes in PEMC were larger than the longitudinal mode based on frequency shift, while Q-value persistence in high viscosity liquids was comparable.…”
mentioning
confidence: 97%
“…Electromechanically-coupled eigenfrequency and frequency response simulations of the printed device were done as previously reported. 42, 43 All studies were performed using commercially available finite element analysis (FEA) software (COMSOL Multiphysics, Version 5.2a). A frequency domain analysis was conducted in 3D using the piezoelectric device interface, which enables the coupling of a solid mechanics problem using the Structural Mechanics module with an electrostatics problem using the AC/DC module.…”
Section: Methodsmentioning
confidence: 99%
“…Damping was modeled as an isotropic structure loss factor (η = 0.01). 42 The mechanical boundary conditions included a fixed constraint condition on all chip faces except the top and bottom faces. No initial deformation, stress, or external forces were applied.…”
Section: Methodsmentioning
confidence: 99%
“…2D, the two trapping zones for the fundamental mode were slightly asymmetric arising from the asymmetric anchor which provides electrically observable impedance-coupled modes. 49 The trapping zone on the cantilever short side was slightly shifted towards the anchor. Movies S1 and S2 † show particle trapping begins with a seeding region and extends from the cantilever surface with time, ultimately resulting in multiple layers of trapped particles at steady state.…”
Section: Particle Trapping In Low-order Resonant Modesmentioning
confidence: 98%