1980
DOI: 10.1007/978-3-642-52201-7
|View full text |Cite
|
Sign up to set email alerts
|

Piezoelektrische Meßtechnik

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
28
0
9

Year Published

1990
1990
2011
2011

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 96 publications
(37 citation statements)
references
References 0 publications
0
28
0
9
Order By: Relevance
“…Measurements were performed with an angular resolution of 0.5 crankangle degrees and a Yokogawa DL708E oscillographic recorder was used. The pressure sensor was calibrated according to the usual method [22] based on a quasi-steady calibration by means of a deadweight tester with NPL and NIST traceability. With this procedure, the relative error obtained from the calibration of the transducer was ±0.7%.…”
Section: Experimental Set-up and Testsmentioning
confidence: 99%
“…Measurements were performed with an angular resolution of 0.5 crankangle degrees and a Yokogawa DL708E oscillographic recorder was used. The pressure sensor was calibrated according to the usual method [22] based on a quasi-steady calibration by means of a deadweight tester with NPL and NIST traceability. With this procedure, the relative error obtained from the calibration of the transducer was ±0.7%.…”
Section: Experimental Set-up and Testsmentioning
confidence: 99%
“…Waves of the bulk acoustic type (BAWs) can be invoked Figure 41. Selected applications of piezoelectric transducers with respect to both the direct piezoelectric effect (active transducer) and the converse piezoelectric effect (passive transducer) [222] (with permission from Springer-Verlag, Heidelberg) Figure 42. Schematic overview of acoustic gravimetric devices, illustrating the principles of wave propagation and design [228] (with permission from VDE-Verlag, Berlin) a) BAW; B) SAW; C) APM; D) LW substrates for microgravimetric applications through the use of either AT-or BT-cut plates derived from a single crystal of a-quartz, where ''AT'' and ''BT'' refer to cuts with specific orientations relative to the main axis of the crystal (see below and [229]).…”
Section: Fundamental Principles and Basic Types Of Transducersmentioning
confidence: 99%
“…The temperature dependence of the relative frequency for various cuts of quartz crystal is shown as a function of the angle of cut in Figure 57 [262]. More detailed theoretical treatments of piezoelectric solids and their properties are provided by [222], [263][264][265]. Another more sophisticated approach based on dynamic quantum mechanics is presented in [266].…”
Section: Theoretical Backgroundmentioning
confidence: 99%
See 1 more Smart Citation
“…En efecto, en este caso, sería necesario desarrollar una herramienta especifica para simular las condiciones cambiantes de presión en cilindro, una tarea demasiado compleja y cara. Por tanto, se ha empleado un método tradicional [185] basado en la calibración cuasi estacionaria, mediante un equipo hidráulico de pesos muertos Hotek 9000 series.…”
Section: A14 Calibración De Los Transductores De Presiónunclassified