2021
DOI: 10.1016/j.expthermflusci.2021.110470
|View full text |Cite
|
Sign up to set email alerts
|

PIV and shadowgraph measurements of thermo-electrohydrodynamic convection in a horizontal aligned differentially heated annulus at different gravity conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 43 publications
1
5
0
Order By: Relevance
“…They also have well-known properties and have a wide range of available viscosities. In particular, silicone oil B5 has often been used during numerous parabolic flight campaigns and laboratory experiments [17,18,20,24], where its compatibility with hollow borosilicate glass micro-sized particles for the use of particle image velocimetry, especially regarding the effect of the radial sedimentation velocity due to the electric gravity was proven [24]. Hence, this study used the following parameters Pr=65, δ=1 and Ga=535 for the present analysis.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…They also have well-known properties and have a wide range of available viscosities. In particular, silicone oil B5 has often been used during numerous parabolic flight campaigns and laboratory experiments [17,18,20,24], where its compatibility with hollow borosilicate glass micro-sized particles for the use of particle image velocimetry, especially regarding the effect of the radial sedimentation velocity due to the electric gravity was proven [24]. Hence, this study used the following parameters Pr=65, δ=1 and Ga=535 for the present analysis.…”
Section: Resultsmentioning
confidence: 99%
“…Many theoretical and numerical analyses have been performed considering μg conditions in the case of stationary cylinders [10,11], as well as for the circular Couette flow [1215]. Experiments under microgravity involved sounding rockets and drop tower experiments [16], as well as parabolic flights [17,18]. The last existing way to perform long duration μg conditions was to experiment onboard the International Space Station, e.g.…”
Section: Introductionmentioning
confidence: 99%
“…Seelig et al (2019) have estimated that for temperature difference 7 K and peak voltage 7 kV, the electric sedimentation velocity measured at the inner cylinder is 6.3 × 10 −6 mm s −1 . Considering the relatively short duration of the μg condition (6 min) and the thermo-electric convective fluid velocity being of the order of 0.1-1 mm s −1 (see Meier et al 2018;Meyer et al 2019;Szabo et al 2021), it is assumed that the sedimentation of the particles can be neglected. Two independent fluid loops are used to maintain the temperature difference T (see figure 2).…”
Section: Experimental Set-upmentioning
confidence: 99%
“…2019; Szabo et al. 2021), it is assumed that the sedimentation of the particles can be neglected.
Figure 2.Schematic drawing of the fluid loops for the temperature control and gap mixing.
…”
Section: Experimental Set-upmentioning
confidence: 99%
See 1 more Smart Citation