2018
DOI: 10.1016/j.anucene.2018.06.024
|View full text |Cite
|
Sign up to set email alerts
|

PIV measurement of cross flow in a rod bundle assisted by telecentric optics and matched index of refraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 32 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…Commonly used model materials are fluorinated ethylene propylene (FEP), polyvinyl acetate (PVAc), polystyrene (PS), and polymethyl methacrylate (PMMA). Among them, FEP has poor transmittance and causes substantial decay of the laser flux [45,46]; PVAc has a low softening point (38 °C) and is unsuitable for medium-and high-temperature tests; PS has poor toughness and is difficult to machine. PMMA, with its good transmittance and easy processing, is the most used model material in flow field visualization experiments.…”
Section: Flow Field Visualization Measurement Technologymentioning
confidence: 99%
“…Commonly used model materials are fluorinated ethylene propylene (FEP), polyvinyl acetate (PVAc), polystyrene (PS), and polymethyl methacrylate (PMMA). Among them, FEP has poor transmittance and causes substantial decay of the laser flux [45,46]; PVAc has a low softening point (38 °C) and is unsuitable for medium-and high-temperature tests; PS has poor toughness and is difficult to machine. PMMA, with its good transmittance and easy processing, is the most used model material in flow field visualization experiments.…”
Section: Flow Field Visualization Measurement Technologymentioning
confidence: 99%
“…It is commonly referred to as the standard fixed focal-length lens. The telecentric lens erases perspective errors [24][25][26]. The hypercentric lens inverts the normal perspective to see almost the entire surface of a three-dimensional object.…”
Section: Introductionmentioning
confidence: 99%
“…Dominguez-Ontiveros et al's and Conner et al's experimental data has been included in the CFD benchmark database (Conner et al, 2013b). With the aid of telecentric optic Xiong et al (2018a) measured the 2D cross flow in a 5 × 5 rod bundle with 2D PIV. More recently, Qu et al (2019a,b,c) carried out the high-fidelity PIV measurement in rod bundle with split mixing vanes.…”
Section: Introductionmentioning
confidence: 99%