2013
DOI: 10.1002/pd.4172
|View full text |Cite
|
Sign up to set email alerts
|

Placental three‐dimensional power Doppler indices in mid‐pregnancy and late pregnancy complicated by gestational diabetes mellitus

Abstract: A decreased placental vascularization could be an adjunct sonographic marker in the diagnosis of diabetic pregnancy in mid-gestation and late gestation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
30
0
5

Year Published

2015
2015
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(36 citation statements)
references
References 22 publications
1
30
0
5
Order By: Relevance
“…We used three-dimensional rendering mode, in which the color and gray value information were processed and combined to give a three-dimensional image (27,28,29). Power Doppler window (pulse repetition frequency at 900Hz and wall filter of 50Hz) was placed over the placenta(s), mapping the vascular tree from basal to chorionic plates at both umbilical cord insertion(s).…”
Section: Ultrasound Examinationmentioning
confidence: 99%
“…We used three-dimensional rendering mode, in which the color and gray value information were processed and combined to give a three-dimensional image (27,28,29). Power Doppler window (pulse repetition frequency at 900Hz and wall filter of 50Hz) was placed over the placenta(s), mapping the vascular tree from basal to chorionic plates at both umbilical cord insertion(s).…”
Section: Ultrasound Examinationmentioning
confidence: 99%
“…The RA is one of the organs sensitive to hypoxia and one of the first organs to have endothelial dysfunction. [12]…”
Section: Introductionmentioning
confidence: 99%
“…Only FI was found to be significantly lower in CHT+GDM compared to CHT, though we expected significantly lower results in case of VI, VFI as well based on an earlier study (22). …”
Section: Discussionmentioning
confidence: 39%
“…We used 3D rendering mode, in which the color and gray value information was processed and combined to give a 3D image (mode cent: smooth, 4/5; FRQ, low; quality, 16; density, 6; enhance, 16; balance, 150; filter, 2; actual power, 2 dB; pulse repetition frequency, 0.9) (22). Power Doppler window (pulse repetition frequency at 900 Hz and wall filter of 50 Hz) was placed over the placenta, mapping the vascular tree from basal to chorionic plates, as this technique shows higher sensitivity because it is based on amplitude instead of mean frequencies to depict the vascular tree (15).…”
Section: Methodsmentioning
confidence: 99%