2003
DOI: 10.1016/s1090-7807(03)00151-4
|View full text |Cite
|
Sign up to set email alerts
|

Planar microcoil-based microfluidic NMR probes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
195
1

Year Published

2006
2006
2016
2016

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 195 publications
(204 citation statements)
references
References 31 publications
4
195
1
Order By: Relevance
“…However, all of these techniques require low temperatures. For liquid samples at room temperature, pioneering work on fabrication of solenoids around capillary tubes (16,24) and microfabrication techniques to create planar coils on semiconductor substrates (1,25) demonstrates that miniaturization of probes is possible and substantially reduces sample quantity while retaining signal sensitivity (15). Solenoidal microcoils detect nanomole quantities with high sensitivity but have not been successfully fabricated below Ϸ300 m inner diameter (26), whereas planar coils on semiconductor substrates are scalable but show lower signal sensitivity due to inhomogeneous broadening and path loss.…”
Section: N Uclear Magnetic Resonance (Nmr) Is a Powerful Analyticalmentioning
confidence: 99%
“…However, all of these techniques require low temperatures. For liquid samples at room temperature, pioneering work on fabrication of solenoids around capillary tubes (16,24) and microfabrication techniques to create planar coils on semiconductor substrates (1,25) demonstrates that miniaturization of probes is possible and substantially reduces sample quantity while retaining signal sensitivity (15). Solenoidal microcoils detect nanomole quantities with high sensitivity but have not been successfully fabricated below Ϸ300 m inner diameter (26), whereas planar coils on semiconductor substrates are scalable but show lower signal sensitivity due to inhomogeneous broadening and path loss.…”
Section: N Uclear Magnetic Resonance (Nmr) Is a Powerful Analyticalmentioning
confidence: 99%
“…6 the Joule heating threshold has been determined for all three side channel lengths (20,50 and 100 m) with a 1 M buffer, as well as for all three buffer concentrations (0.25, 0.5 and 1 M) in a pump with 20 m long side channels. Table 4 summarizes those values.…”
Section: Joule Heating and Power Consumptionmentioning
confidence: 99%
“…The MHD body force (180.5 Pa) and flow velocity (2.8 mm s −1 ) performance in NMR environment of our pump surpassed any previously published MHD pumps of similar dimensions (see Table 1). The final aim of this work is to integrate our MHD pump together with planar coils in a microfluidic system for NMR analysis [20]. The high performance of the pump at relatively low flow rates is seen as an asset for NMR and MRI applications.…”
Section: Measurements In Nmr Superconductive Magnetmentioning
confidence: 99%
“…Massin et al [25] micromachined planar copper electroplated microcoils on a Pyrex-glass substrate with etched microchannels. They recorded the 1 H spectrum at 300 MHz for 160 mg sucrose in 470 nL D 2 O (a 1 M solution) using two different designs of the microcoil.…”
Section: Nmr Detectionmentioning
confidence: 99%