2012
DOI: 10.1016/j.ijrobp.2012.02.025
|View full text |Cite
|
Sign up to set email alerts
|

Planning Hybrid Intensity Modulated Radiation Therapy for Whole-breast Irradiation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
29
0
3

Year Published

2013
2013
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(34 citation statements)
references
References 20 publications
2
29
0
3
Order By: Relevance
“…Moreover, improvements in the uniformity of dose to the target volume and conformality may be achieved by adding 2 anterior oblique IMRT beams to the 4-field hybrid technique (6-field hybrid IMRT). In a clinical trial conducted by Farace et al (21), hybrid IMRT was performed by direct aperture optimization. However, when treatment goals were not achieved by using a 4-field technique, a 6-field technique was applied.…”
Section: Dosimetric Comparison Of Left-sided Whole Breast Irradiationmentioning
confidence: 99%
“…Moreover, improvements in the uniformity of dose to the target volume and conformality may be achieved by adding 2 anterior oblique IMRT beams to the 4-field hybrid technique (6-field hybrid IMRT). In a clinical trial conducted by Farace et al (21), hybrid IMRT was performed by direct aperture optimization. However, when treatment goals were not achieved by using a 4-field technique, a 6-field technique was applied.…”
Section: Dosimetric Comparison Of Left-sided Whole Breast Irradiationmentioning
confidence: 99%
“…Farace et al tested hybrid IMRT using semi-automated methods and use of an optimization volume as the target objective [18]. Goals were achieved in 61 patients with 2 conventional open and 2 IMRT tangents, similar to our technique.…”
Section: Discussionmentioning
confidence: 71%
“…Farace et al19 similarly compared tangential and non-tangential beam arrangements for hybrid IP IMRT plans utilizing a semi-automated method and a plan optimization volume set as a target objective during IP 19. The tangential beam arrangement was a four-field technique (two conventional open plus two IP IMRT tangents), and the non-tangential beam arrangement was a six-field technique where two non-tangential (anterior-oblique) IP IMRT beams were added.…”
Section: Types Of Breast Imrt Techniquesmentioning
confidence: 99%
“…Both studies demonstrated that the merits of utilizing hybrid IP IMRT lie in its largely automated process while achieving a comparable plan quality to FP FIF IMRT yet reducing planning time, reducing manual process during planning as well as dependence on dosimetrist’s expertise. The limited monitor units (MU) contribution from IP IMRT beams allowed QA to be less taxing compared to full IP IMRT 19. An added advantage of utilizing hybrid IP IMRT is the use of open fields as a main radiation source as this makes planned dosimetry less sensitive to changes in breast shape and setup inaccuracies 22…”
Section: Types Of Breast Imrt Techniquesmentioning
confidence: 99%