2015
DOI: 10.1186/s40169-015-0071-4
|View full text |Cite
|
Sign up to set email alerts
|

Plasma preparation to measure FDA‐approved protein markers by selected reaction monitoring

Abstract: Background The development of commercially available panels for human blood plasma screening via selected reaction monitoring (SRM) offers reliable, cost-efficient and highly-standardized discovery and validation of protein biomarkers. However, protein detection by SRM can be hampered by interfering peptide fragment ions. To estimate the influence of interference on protein detection, we performed different types of sample preparation and implemented SRM measurements for well-characterized protein… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…One potential avenue for achieving greater sensitivity is the immunoaffinity depletion of high abundance protein, as is common for SRM plasma biomarker quantitation. 62 , 63 This could prove to be a useful avenue of further research, especially for foods characterized by a dominant protein-contributing ingredient; for example, depleting wheat protein in breads or cookies when quantitating milk proteins.…”
Section: Methods Of Allergen Quantitationmentioning
confidence: 99%
“…One potential avenue for achieving greater sensitivity is the immunoaffinity depletion of high abundance protein, as is common for SRM plasma biomarker quantitation. 62 , 63 This could prove to be a useful avenue of further research, especially for foods characterized by a dominant protein-contributing ingredient; for example, depleting wheat protein in breads or cookies when quantitating milk proteins.…”
Section: Methods Of Allergen Quantitationmentioning
confidence: 99%
“…The protein digestion can be performed using trypsin at 37 °C for three hours with stirring. The trypsinization is then terminated by adding trichloroacetic acid, the pH adjusted, the trypsinized plasma is dried, resolved in liquid chromatography solution, spiked with isotypically labeled peptide standard and then used for mass spectrometric analysis [ 28 ]. Sample collection and preparation are critical steps to obtain useful information in clinical proteomics analyses.…”
Section: Materials To Be Evaluatedmentioning
confidence: 99%
“…Indeed, utilizing the undepleted plasma, in the same way as immunological based assays, would be the ideal solution to bypass all of the above issues. However, studies showed that MRM‐MS of the undepleted plasma typically had the lower LOD and the lower LOQ in the high nanogram per milliliter to low microgram per milliliter range of target proteins , while the LOD and LOQ could be extended to low nanogram per milliliter range by applying plasma prefractionation prior to MS analysis . It seems that in MS‐based assay plasma prefractionation should be considered and performed depending on the concentration range of target proteins and the sensitivity of MS platforms.…”
Section: Perspective In Clinical Applicationsmentioning
confidence: 99%