2005
DOI: 10.1016/j.cccn.2005.03.035
|View full text |Cite
|
Sign up to set email alerts
|

Plasmatic antioxidant capacity due to ascorbate using TEMPO scavenging and electron spin resonance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 27 publications
0
8
0
Order By: Relevance
“…To convert the decay rate into an ascorbate equivalent concentration, we prepared a calibration curve with ascorbate-TEMPOL samples at known ascorbate concentration. The final ascorbate equivalent concentrations were normalized to the values of control rats, set as 100%, to give relative antioxidant levels [19].…”
Section: Antioxidant Capacity Of Plasma and Heart Homogenatesmentioning
confidence: 99%
“…To convert the decay rate into an ascorbate equivalent concentration, we prepared a calibration curve with ascorbate-TEMPOL samples at known ascorbate concentration. The final ascorbate equivalent concentrations were normalized to the values of control rats, set as 100%, to give relative antioxidant levels [19].…”
Section: Antioxidant Capacity Of Plasma and Heart Homogenatesmentioning
confidence: 99%
“…27,28 Another advantage is the application of spectrophotometric detection, especially when compared to high cost, high maintenance detectors for ESR, 10 for instance.…”
Section: Introductionmentioning
confidence: 99%
“…3 For this reason, the assessment of total antioxidant capacity (TAC) of biological fluids will be a useful biomedical tool that can assist the evaluation of physiological, environmental and nutritional factors that influence the human redox status. 4 In this regard, several human biological fluids have been used as samples for the in vitro evaluation of TAC, including plasma, [5][6][7][8][9][10][11][12] serum, [13][14][15][16] urine, 8,12,17 saliva, 15 cerebrospinal fluid, 18 tears, 19 breast milk 20 and also semen. 21 Various batch methodologies based on electron spin resonance (ESR), 10 electrochemical, 6,11 chemiluminescence (CL), 8,15,16 fluorometric, 7 and UV-Vis spectrophotometric 5,13,14 detection have been proposed.…”
Section: Introductionmentioning
confidence: 99%
“…The ascorbic acid serum status was determined by electron spin resonance (ESR) spectroscopy (X band ESR Spectrometer Bruker ECS 106, German) as described elsewhere [35]. TEMPO (2,2,5,5-tetramethyl-4-piperidin-1-oxyl) (Sigma Chemical Co., USA) stock solution (6.3 mmol/L) was prepared with 96% ethanol (Laboratorios Cicarelli, Argentina) and stored at 4ºC until needed.…”
Section: Tempo Scavenging Assaymentioning
confidence: 99%