2022
DOI: 10.1016/j.biopha.2022.113201
|View full text |Cite
|
Sign up to set email alerts
|

Plasmatic renin-angiotensin system in normotensive and hypertensive patients hospitalized with COVID-19

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 41 publications
0
9
0
Order By: Relevance
“…Despite these findings, current research on cACE2 levels and activity in several cohorts of COVID-19 patients has generated controversy. These studies range from very high or high[ 49 , 50 , 52 , 54 , 55 , 57 , 62 ] to unaltered or even decreased cACE2 levels[ 51 , 58 , 60 ] compared to controls. The effect of age and gender on cACE2 was explored, and there was a trend for cACE2 levels to rise with age.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Despite these findings, current research on cACE2 levels and activity in several cohorts of COVID-19 patients has generated controversy. These studies range from very high or high[ 49 , 50 , 52 , 54 , 55 , 57 , 62 ] to unaltered or even decreased cACE2 levels[ 51 , 58 , 60 ] compared to controls. The effect of age and gender on cACE2 was explored, and there was a trend for cACE2 levels to rise with age.…”
Section: Discussionmentioning
confidence: 99%
“…In 93 hospitalized COVID-19 patients and 40 healthy people, the levels of plasmatic cACE2 protein, ACE2 enzymatic activity, Ang II, and Ang-(17) were compared by Silva et al [ 60 ]. They also compared the parameters of COVID-19 between normotensive and hypertensive subjects.…”
Section: Circulating Ace2 In Covid-19 Patientsmentioning
confidence: 99%
“…Intraassay and inter-assay variability were 13.7 AE 2.3 and 12.4 AE 3.1%, respectively. ACE2 activity was measured using an ACE2-quenched fluorescent substrate (Mca-Ala-Pro-Lys(Dnp)-OH; Enzo Life Sciences) as described [5].…”
Section: Methodsmentioning
confidence: 99%
“…Whole blood was collected into EDTA-tubes containing 0.44 mmol/l o-phenanthroline, 1 mmol/l sodium-para-chloromercuribenzoate and 25 mmol/l EDTA for Ang II and Ang-(1–7) measurement and a separate tube without those inhibitors for ACE2 activity. Angiotensin levels were quantified by radioimmunoassay as described [5]. Intra-assay and inter-assay variability were 13.7 ± 2.3 and 12.4 ± 3.1%, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…Blood samples were collected in EDTA-tubes containing 0.44 mmol/L o-phenanthroline, 1 mmol/L Na + para-chloromercuribenzoate and 25 mmol/L EDTA. Samples were centrifuged at 3,000 xg for 20 min at 4℃ and plasma were loaded into SepPak C18 cartridges for angiotensins extraction as previously described [8]. Because angiotensin may not be completely extracted from the cartridge, angiotensin recovery was calculated and corrected for each sample.…”
Section: Ang II and Ang-(1-7) Levels Measurementmentioning
confidence: 99%