2022
DOI: 10.1016/j.cmpb.2022.107006
|View full text |Cite
|
Sign up to set email alerts
|

Plate configuration for biological reconstructions of femoral intercalary defect - a finite element evaluation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 32 publications
0
5
0
Order By: Relevance
“…Hence, evaluating the current problems of allograft reconstruction techniques and optimizing treatment strategies is imperative [14,31]. Better initial stability can promote bone healing and reduce the risk of nonunion or implant failure [10,15]. Hence, Paul and Abraham [13] combined a CFR-PEEK plate and nailing for intercalary resection with tibial allograft, concluding that larger comparative studies are needed to ensure that CarboFix CFR-PEEK implants may be safe and effective for intercalary resection.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Hence, evaluating the current problems of allograft reconstruction techniques and optimizing treatment strategies is imperative [14,31]. Better initial stability can promote bone healing and reduce the risk of nonunion or implant failure [10,15]. Hence, Paul and Abraham [13] combined a CFR-PEEK plate and nailing for intercalary resection with tibial allograft, concluding that larger comparative studies are needed to ensure that CarboFix CFR-PEEK implants may be safe and effective for intercalary resection.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, when applied to young patients, they cannot adjust their function to the natural growth of limbs, which is inappropriate. Biologic reconstructions include the possibility of intercalary allografts, fibular grafts, bone transportation, and distraction osteogenesis [10]. The outcome of the biologic reconstruction depends on the patient's osteogenic viability and the initial stability of the reconstruction.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Careful consideration to durable rigid fixation is advised, but we cannot recommend a specific fixation method because rods or plates were used in our patients. Some studies have reported that dual locking provides the most rigid and strong fixation, using finite-element analysis [16,45].…”
Section: Proportion Of Patients With Union In Tumordevitalized Autogr...mentioning
confidence: 99%