2011
DOI: 10.1097/brs.0b013e3181fea49c
|View full text |Cite
|
Sign up to set email alerts
|

Plate-Only Open Door Laminoplasty Maintains Stable Spinal Canal Expansion with High Rates of Hinge Union and No Plate Failures

Abstract: Plate-only laminoplasty provided stable reconstruction of an expanded laminar arch with no failures, dislodgements, adverse neurologic consequences, or premature closures in 217 levels. Ninety-three percent of hinges demonstrated radiographic union at 12 months, and even those that did not heal by CT scan criteria maintained patent expansion of the spinal canal without adverse neurologic consequences. Supplemental bone graft does not appear necessary when plated laminoplasty is performed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
88
3
1

Year Published

2013
2013
2019
2019

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 84 publications
(95 citation statements)
references
References 7 publications
3
88
3
1
Order By: Relevance
“…Previous reports showed that the hinge fusion rate at 1 year after the operation was 93 % with mini-plates [9], 98 % with hydroxyapatite spacers, and 97 % with autogenous spacers [7], In the present study, the overall fusion rate was 98.2 % at a mean of 12.7 months after the operation, and was 100 % at follow-ups performed C1 year after the operation. These values were comparable or slightly superior to those for the other techniques.…”
Section: Discussionsupporting
confidence: 56%
See 1 more Smart Citation
“…Previous reports showed that the hinge fusion rate at 1 year after the operation was 93 % with mini-plates [9], 98 % with hydroxyapatite spacers, and 97 % with autogenous spacers [7], In the present study, the overall fusion rate was 98.2 % at a mean of 12.7 months after the operation, and was 100 % at follow-ups performed C1 year after the operation. These values were comparable or slightly superior to those for the other techniques.…”
Section: Discussionsupporting
confidence: 56%
“…Later, various materials were used to keep the laminae open, such as autologous bone, mini-plates, and ceramic spacers [6]. Furthermore, several studies have investigated bony healing after laminoplasty [7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…15,21,35 However, delayed spinal cord compression by dislodged HA spacers has been reported. 21,26 Retrospective studies have shown bony union rates of 61% to 77% achieved by using HA spacers after doubledoor laminoplasty.…”
Section: Bone-spacer Bonding and Bony Unionmentioning
confidence: 99%
“…In one study of plateonly laminoplasty, at one year the hinge non-union rate was 7% and the screw pullout rate was 2.3%, but there was no plate dislodgement or laminoplasty closure. 18 The major risks of lateral mass screw fixation are damage to the vertebral artery, spinal nerves, or facet joints. Unicortical purchase eliminates the risk of damaging neurovascular structures.…”
Section: Discussionmentioning