“…In part, lower readings from the ELPI can be attributed to the fact that filters adsorb gaseous hydrocarbons in addition to trapping particulate matter. The study by Chase et al (2004) suggests that under the sampling conditions of our dilution system Teflo and quartz filters on average collect the equivalent of 0.5-1 mg/km and 0.8-1.4 mg/km gaseous material, respectively, roughly 2% of the gravimetric PM mass. As discussed in the following section, however, systematic differences can also arise from the analysis of the ELPI data, for example from uncertainties in the soot effective density and the geometric standard deviation of the soot mobility distribution.…”
Section: Figmentioning
confidence: 99%
“…In part, lower readings from the ELPI can be attributed to the fact that filters adsorb gaseous hydrocarbons in addition to trapping particulate matter. The study by Chase et al (2004) suggests that under the sampling conditions of our dilution system Teflo and quartz filters on average collect the equivalent of 0.5-1 mg/km and 0.8-1.4 mg/km gaseous material, respectively, roughly 2% of the gravimetric PM mass. As discussed in the following section, however, systematic differences can also arise from the analysis of the ELPI data, for example from uncertainties in the soot effective density and the geometric standard deviation of the soot mobility distribution.…”
Section: Figmentioning
confidence: 99%
“…It can also be used to convert particle size distributions to particle mass distributions from which total particle mass concentration can be determined. The integrated particle size distribution (IPSD) method is seen as an option for particle mass emission factor measurement for the modern vehicles (Liu et al 2009(Liu et al , 2012, which produce very few particles and where gravimetric measurement is difficult due to the low mass collected and the significance of errors due to sampling artifacts (Chase et al 2004). The effective density function for GDI particles has been measured by Maricq and Xu (2004), Symonds et al (2008), and Quiros et al (2015).…”
Section: Introductionmentioning
confidence: 99%
“…Quartz fiber filters have been found to be prone to filter artifacts (Schauer et al 1999;Lipsky and Robinson 2006), and therefore, current legislation recommends using Teflon-coated glass fiber or membrane filters for PM exhaust measurements. However, recent studies show that Teflon filters also suffer from sampling artifacts (Chase et al 2004;Khalek 2005 artifact of 10%-20% for Teflon membrane filters and 30%-50% for Teflon-coated glass fiber filters. The positive artifact is believed to be dominant over the negative one when sampling diluted vehicle exhaust (Chase et al 2004).…”
Section: Introductionmentioning
confidence: 99%
“…However, recent studies show that Teflon filters also suffer from sampling artifacts (Chase et al 2004;Khalek 2005 artifact of 10%-20% for Teflon membrane filters and 30%-50% for Teflon-coated glass fiber filters. The positive artifact is believed to be dominant over the negative one when sampling diluted vehicle exhaust (Chase et al 2004).…”
Section: Introductionmentioning
confidence: 99%