2021
DOI: 10.3389/fphys.2021.627088
|View full text |Cite
|
Sign up to set email alerts
|

Poincaré Plot Area of Gamma-Band EEG as a Measure of Emergence From Inhalational General Anesthesia

Abstract: The Poincaré plot obtained from electroencephalography (EEG) has been used to evaluate the depth of anesthesia. A standalone EEG Analyzer application was developed; raw EEG signals obtained from a bispectral index (BIS) monitor were analyzed using an on-line monitoring system. Correlations between Poincaré plot parameters and other measurements associated with anesthesia depth were evaluated during emergence from inhalational general anesthesia. Of the participants, 20 were adults anesthetized with sevoflurane… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 59 publications
0
4
0
Order By: Relevance
“…The electroencephalographic data were analyzed using the EEG analyzer version 49. 1 In the EEG analyzer system, raw electroencephalographic signals from a bispectral index (BIS) monitor were collected at a sampling rate of 128 Hz. Continuous data from the preceding 8-second epoch were bandpass-filtered (0.5–50 Hz), and each epoch was applied to a Blackman window function, followed by a fast Fourier transform for power spectrum analysis and bispectral analysis.…”
Section: Case Descriptionmentioning
confidence: 99%
“…The electroencephalographic data were analyzed using the EEG analyzer version 49. 1 In the EEG analyzer system, raw electroencephalographic signals from a bispectral index (BIS) monitor were collected at a sampling rate of 128 Hz. Continuous data from the preceding 8-second epoch were bandpass-filtered (0.5–50 Hz), and each epoch was applied to a Blackman window function, followed by a fast Fourier transform for power spectrum analysis and bispectral analysis.…”
Section: Case Descriptionmentioning
confidence: 99%
“…At the phase of emergence from general anesthesia, sugammadex (4 mg/kg) was administered before extubation. To acquire EEG data, we used the software application EEG Analyzer [12,13], through which raw EEG signals via an RS-232 interface of a VISTA A-3000 BIS monitor (VISTA Application revision 3.22, Platform revision 2.03, Medtronic, Minneapolis, MN, USA) were recorded on a personal computer (Surface Pro 4, Microsoft Co., Redmond, WA, USA) as text les. Additionally, various parameters associated with anesthetic depth were acquired via a BIS Quatro sensor mounted on the frontal regions according to the manufacturer's recommendations.…”
Section: Anesthesia Management and Data Acquisitionmentioning
confidence: 99%
“…We previously developed a software application named “EEG Analyzer” to obtain raw EEG signals from a BIS A-2000 monitor (version 3.23; Medtronic, Minneapolis, MN, USA) through an RS-232 interface [ 12 ]. A BIS Quatro sensor was attached on the frontal region, in accordance with the manufacturer’s recommendations and single frontal channel EEG was recorded.…”
Section: Data Acquisitionmentioning
confidence: 99%