Abstract:Liver transplantation (LT) is a serious hemostatic challenge in patients with portal vein thrombosis (PVT). Advances in monitoring systems have improved surgery in this setting. We report the successful application of a point-of-care (POC) rotational viscoelastic thromboelastometry-guided (TEM) testing system (ROTEM) which allowed management of coagulation during LT in a 64-year-old cirrhotic patient with a model for end-stage liver disease (MELD) score of 16. Perioperatively, the patient showed complete PVT, … Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.