2016
DOI: 10.1016/j.msec.2016.06.081
|View full text |Cite|
|
Sign up to set email alerts
|

Poly-dopamine-beta-cyclodextrin: A novel nanobiopolymer towards sensing of some amino acids at physiological pH

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
22
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 53 publications
(22 citation statements)
references
References 64 publications
(20 reference statements)
0
22
0
Order By: Relevance
“…Based on excellent electroactivity of PDA-β-CD ilm towards determination of some amino acids and at continuing our previously report [20], in this report the performance of PDA-β-CD-GCE was evaluated towards electrooxidation and determination of L-Trp. The aim of this communication is merely to expand application of PDA-β-CD-GCE towards the kinetic and analytical investigates of L-Trp.…”
Section: Introductionmentioning
confidence: 73%
See 2 more Smart Citations
“…Based on excellent electroactivity of PDA-β-CD ilm towards determination of some amino acids and at continuing our previously report [20], in this report the performance of PDA-β-CD-GCE was evaluated towards electrooxidation and determination of L-Trp. The aim of this communication is merely to expand application of PDA-β-CD-GCE towards the kinetic and analytical investigates of L-Trp.…”
Section: Introductionmentioning
confidence: 73%
“…All of experimental procedure is similar to our previous report [20]. All chemicals used were of analytical grade from Merck (Darmstadt, Germany) and were used without further puri ication.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, PARG‐CS‐GCE was prepared in this step. As we know, the electron withdrawing oxygen‐containing groups on GQDs are beneficial to the combination with CS from the electrostatic point of view, since CS dissolved in acid (HCl in the present work) is positively charged . Therefore, at the final modification step, GQDs was deposited on the surface of PARG‐CS‐GCE from GQDs aqueous solution (0.002 g/mL) in the potential range from 0 to 1.0 V versus Ag/AgCl at a scan rate of 100 mV/s using cyclic voltammetry techniques (Figure 2).…”
Section: Methodsmentioning
confidence: 99%
“…Recent studies have demonstrated that electropolymerization has received great attention because of its simplicity, selectivity, and sensitivity toward analytes, strong adherence of polymer film to electrode surface, and ability to provide larger surface area by forming homogeneous membrane . Various interface based on poly amino acid have been described in the literatures for the development of some electrochemical sensors . Moreover, the combination of these polymers with nanomaterials make them attractive for the electrochemical analysis.…”
Section: Introductionmentioning