2013
DOI: 10.3144/expresspolymlett.2013.39
|View full text |Cite
|
Sign up to set email alerts
|

Poly(ethylene glycol)-poly(tetrahydrofuran)-poly(ethylene glycol) triblock copolymer : Synthesis, crystallization behavior and novel morphology

Abstract: Abstract. Poly(ethylene glycol)-poly(tetrahydrofuran)-poly(ethylene glycol) (PEG-PTHF-PEG) triblock copolymer was synthesized by ring-opening polymerization of ethylene oxide using sodium alcoholate of PTHF as the macroinitiator. Its crystallization behavior and formation mechanisms of different crystal structures were studied. The study showed that the molecular weight of PEG-PTHF-PEG exhibited a significant effect on its crystallization: that is, with the increase of the copolymer's molecular weight, the cry… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 43 publications
1
5
0
Order By: Relevance
“…M bias ¼ M n;SECÀMALLS À M n;MALDIÀTOF M n;SECÀMALLS ¼ 9:75% (16) As proved by titration, the chemical heterogeneity of PEG-PTHF-PEG triblock copolymer rarely affected the reliability of SEC/MALS measurement. Generally, the influence of chemical heterogeneity of copolymers on SEC/MALS measurement included two aspects.…”
Section: Comparison Of Different Methodsmentioning
confidence: 96%
See 2 more Smart Citations
“…M bias ¼ M n;SECÀMALLS À M n;MALDIÀTOF M n;SECÀMALLS ¼ 9:75% (16) As proved by titration, the chemical heterogeneity of PEG-PTHF-PEG triblock copolymer rarely affected the reliability of SEC/MALS measurement. Generally, the influence of chemical heterogeneity of copolymers on SEC/MALS measurement included two aspects.…”
Section: Comparison Of Different Methodsmentioning
confidence: 96%
“…However, data from neither SEC/ MALS nor titration was consistent with that of MALDI-TOF MS, suggesting that the molecular weight determined by SEC/MALS was reliable, but the result of MALDI-TOF MS was, indeed, smaller than the true value. With SEC/MALS as a reference method, the result of MALDI-TOF MS showed a deviation of 9.75%, according to Equation (16).…”
Section: Comparison Of Different Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Poly(1,5‐cyclooctadiene) (PCOD, M n = 3300 g mol −1 , M w / M n = 1.69) was synthesized via ring‐opening metathesis polymerization using cis‐1,4‐diacetoxy‐2‐butene as the chain transfer agent . Poly(ethylene glycol) (PEG, M n = 1500 g mol −1 , M w / M n = 1.24) was prepared via the modification of terminal groups . PEG‐PTHF‐PEG triblock polymer (M n = 2000 g mol −1 , M w / M n = 1.22) was prepared via anionic polymerization.…”
Section: The Synthesis Of Mbcs Using Different Macromonomersmentioning
confidence: 99%
“…[45] Poly(ethylene glycol) (PEG, M n = 1500 g mol −1 , M w /M n = 1.24) was prepared via the modification of terminal groups. [46] PEG-PTHF-PEG triblock polymer (M n = 2000 g mol −1 , M w /M n = 1.22) was prepared via anionic polymerization. The detailed synthesis routes for the polymers and the structural characterization of macromonomers are described in the Supporting Information.…”
Section: In This Study a New Strategy To Synthesize Random And Altermentioning
confidence: 99%