2013
DOI: 10.1016/j.ijrefrig.2012.11.023
|View full text |Cite
|
Sign up to set email alerts
|

Pool boiling data and prediction method for enhanced boiling tubes with R-134a, R-236fa and R-1234ze(E)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
8
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(10 citation statements)
references
References 30 publications
2
8
0
Order By: Relevance
“…This insensitivity to increasing temperature/pressure for enhanced surfaces was also reported by van Rooyen and Thome [14]. This indicates that the coating itself may limit heat dissipation.…”
Section: Resultssupporting
confidence: 82%
See 1 more Smart Citation
“…This insensitivity to increasing temperature/pressure for enhanced surfaces was also reported by van Rooyen and Thome [14]. This indicates that the coating itself may limit heat dissipation.…”
Section: Resultssupporting
confidence: 82%
“…Yang et al [13] compared the thermal performance of various commercially available "Turbo" tubes (manufactured by Wolverine Tube, Inc.) in HFC-134a. Similarly, van Rooyen and Thome [14] compared the vapor generation patterns from two commercially available enhanced tubes in HFC-134a, HFC-236fa, and HFC-1234ze(E). Similarly, van Rooyen and Thome [14] compared the vapor generation patterns from two commercially available enhanced tubes in HFC-134a, HFC-236fa, and HFC-1234ze(E).…”
Section: Introductionmentioning
confidence: 99%
“…The experimental data have been obtained for seven kinds of fluids (water, ethanol, CCl 4 , acetone, n-hexane, R113, R141b) and for the plain surfaces without capillary structures under variable pressure. These surfaces include ordinary metal, metal with a coating and nonmetals of high thermal conductivity.…”
Section: Introductionmentioning
confidence: 99%
“…van Rooyen and J.R. Thome [4] studied Turbo-B5 and Gewa-B5 enhanced surfaces. The experiment were carried out with used refrigerants R-134a, R-236fa and R-1234ze(E).…”
Section: Introductionmentioning
confidence: 99%
“…Diani et al [136] tested R1234ze(E) inside a 3.4 mm microfin tube, in this case R1234ze(E) flow boiling HTC was around 9% lower than those obtained with R134a. Van Rooyen and Thome [140] investigated pool boiling data for enhanced boiling tubes and developed a prediction method based on a boiling heat transfer mechanism in the near-wall region. The R1234ze(E) HTC was 11% lower than R134a Wolverine…”
Section: R1234ze(e) Htc Falls More At Low Vapour Qualities Conclusiomentioning
confidence: 99%