2007
DOI: 10.1016/j.bios.2006.11.026
|View full text |Cite
|
Sign up to set email alerts
|

Portable 24-analyte surface plasmon resonance instruments for rapid, versatile biodetection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
53
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 134 publications
(53 citation statements)
references
References 24 publications
0
53
0
Order By: Relevance
“…This change in refractive index is measured in real time, and the result is plotted as response or resonance units (RUs) versus time (a sensorgram) 25 . The miniature SPR sensing chip, described by Soelberg 26 , et al and Chinowsky 27,28 , et al, is a fully integrated SPR sensor element. Its main components ( Fig.…”
Section: Gold Nanoparticle-enhanced Surface-plasmonmentioning
confidence: 99%
“…This change in refractive index is measured in real time, and the result is plotted as response or resonance units (RUs) versus time (a sensorgram) 25 . The miniature SPR sensing chip, described by Soelberg 26 , et al and Chinowsky 27,28 , et al, is a fully integrated SPR sensor element. Its main components ( Fig.…”
Section: Gold Nanoparticle-enhanced Surface-plasmonmentioning
confidence: 99%
“…Attempts to integrate SPR biosensor apparatus, in order to reduce size and cost, have been proposed, like the use of: polymer-based prisms, using packaged (Chinowsky et al, 2003;Chinowsky et al, 2007;Elkind et al, 1999) or non-packaged arrangements (Loureiro et al, 2009;Loureiro et al, 2011;Moreira et al, 2009 andThirstrup et al, 2004), conventional (Cennamo et al 2013) and microstructured (Dash and Jha, 2014) optical fibers, silicon-based devices (Ghosh andRay, 2015 andPatskovsky et al, 2003) and nanoparticles-based devices (Atar et al, 2015;Rivero et al, 2012;Sener et al, 2011 andWillets andVan Duyne, 2007). For the nanoparticles-based devices the associated physics is different than SPR physics and the phenomenon is known as Localized SPR or LSPR.…”
Section: Theoretical Aspectsmentioning
confidence: 99%
“…Companies such as Texas Instrument (Spreeta) [4,5], K-MAC (Biochip Analyzer, SPRmicro), Seattle Sensor Systems (SPIRIT) [6], and Möbius advanced technology (handheld SPR) currently market portable instruments. The RI resolution of portable instruments is of the order of~2×10 −6 refractive index units (RIU), in comparison with~2×10 −7 RIU [6][7][8] for a high-performance laboratory SPR instrument. The RI resolution refers to the smallest change in RI that it is possible to monitor.…”
mentioning
confidence: 99%
“…In the last decade, portable SPR devices have been used for detection of analytes ranging from small to large molecules or bacteria [6]. Because of the small change in effective refractive index of small molecules, a competitive immunoassay is usually performed to enhance the SPR response and detect these molecules (Fig.…”
mentioning
confidence: 99%