“…The obtained trend of age-related changes of AGE agrees with the results of Refs. [6,9,14] for all the three ratios MR UV , MR G , MR UVG due to the small difference of the linear regression parameters (see Table 2). One can see that in the case of considering only the scattering and absorption in the fluorescence emission band, the ratio RF G is characterised by relatively large coefficients of variation.…”
Section: Results Of the Fluorimeter Testingmentioning
confidence: 99%
See 2 more Smart Citations
“…The obtained trend of age-related changes of AGE agrees with the results of Refs. [6,9,14] for all the three ratios MR UV , MR G , MR UVG due to the small difference of the linear regression parameters (see Table 2). One can see that in the case of considering only the scattering and absorption in the fluorescence emission band, the ratio RF G is characterised by relatively large coefficients of variation.…”
Section: Results Of the Fluorimeter Testingmentioning
confidence: 99%
“…Detailed description of the function and choice justification of the coloured optical glass UFS6 is given in Ref. [14]. The UV radiation purified from the longwave component 3 through the window in the metallic case of the device 4, covered with the protective glass 5 (microscope slide 1 mm thick), is incident on the fluorescing object (forearm inner side) 6, applied to the glass plate from outside.…”
Section: Functional Diagram Of the Fluorimetermentioning
confidence: 99%
See 1 more Smart Citation
“…we have h  10 mm. Clinically tested devices [8,16] diagnose a skin area with a characteristic size of 6 -10 mm. A diagnosed area of less than 1 mm in size can hardly be representative.…”
Section: Optimization Of the Design Parameters Of A Fluorimeter Usingmentioning
confidence: 99%
“…From original, universal, research spectrofluorometers it shall differ in compactness, simplicity of construction and operation at the expense of optimized under the decision of the task set above by optical, electronic and algorithmic structures, and from instruments of the AGE Reader family -the budgetary element basis and easy replicability. The on-stage performance group managed to create two prototypes of the fluorimeter [15,16] meeting the advanced criteria, first of which, single-channel, allowed to validate experimentally the made circuitry decisions by convincing demonstration of its ability to register very feeble radiation of AFR in the presence of destabilizing operational factors, and the second, being dual-channel, -as in laboratory, and in case of approbation in Regional clinical hospital of V. D. Seredavin showed ability to register age features of AFR and pathological processes at the patients having coronary heart disease.…”
Section: Introductionmentioning
confidence: 99%