2020
DOI: 10.1123/jsr.2019-0210
|View full text |Cite
|
Sign up to set email alerts
|

Portable, One-Dimensional, Trunk-Flexor Muscle Strength Measurement System

Abstract: Trunk-flexor muscle strength plays a fundamental role in athletic performance, but objective measurements are usually obtained using expensive and nonportable equipment, such as isokinetic dynamometers. The aim of this study was to assess the concurrent validity of a portable, one-dimensional, trunk-flexor muscle strength measurement system (Measurement System) that uses calibrated barbells and the reliability of the measurements obtained using the Measurement System, by conducting test–retests. As a complemen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…Each evaluation session lasted for 2 weeks with a break of at least 24 h between each one. This 24-h interval was chosen in order to avoid the impact of fatigue resulting from two sessions being too close together [ 19 , 20 ]. Only the data of the last three evaluation sessions (A2, B1, and B2) were analyzed, with the first session (A1) serving as a familiarization and therefore the results of this session were not considered in the analysis of the data.…”
Section: Methodsmentioning
confidence: 99%
“…Each evaluation session lasted for 2 weeks with a break of at least 24 h between each one. This 24-h interval was chosen in order to avoid the impact of fatigue resulting from two sessions being too close together [ 19 , 20 ]. Only the data of the last three evaluation sessions (A2, B1, and B2) were analyzed, with the first session (A1) serving as a familiarization and therefore the results of this session were not considered in the analysis of the data.…”
Section: Methodsmentioning
confidence: 99%
“…Regarding the construct validity, values obtained from the loading cell were correlated with those from the barbell's weight, indicating sufficient validity for trunk flexion strength [48]. However, there was very low-quality evidence due to extremely serious ROB and imprecision.…”
Section: Digital Loading Cell Asymptomatic Individualsmentioning
confidence: 93%
“…Few studies, 8 out of 32, investigated reliability in spinal pain populations, and just two [48,59] investigated validity. This raises concern regarding any reported evaluation of efficacy of rehabilitation programs in individuals with spinal pain [60].…”
Section: Spinal Pain Populationmentioning
confidence: 99%