2017
DOI: 10.1007/s00348-017-2330-1
|View full text |Cite
|
Sign up to set email alerts
|

Positron emission particle tracking in pulsatile flow

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(11 citation statements)
references
References 23 publications
0
11
0
Order By: Relevance
“…N LoR can be estimated for a given particle as the number of LoR passing within (w + 0.5) voxels of its calculated position. Tracer locations from individual timesteps can then be linked into trajectories by the nearest-neighbours method described in [85] and section 5.3, or the projection method described in [47,94].…”
Section: The Feature Point Identification Methods (Fpi)mentioning
confidence: 99%
See 2 more Smart Citations
“…N LoR can be estimated for a given particle as the number of LoR passing within (w + 0.5) voxels of its calculated position. Tracer locations from individual timesteps can then be linked into trajectories by the nearest-neighbours method described in [85] and section 5.3, or the projection method described in [47,94].…”
Section: The Feature Point Identification Methods (Fpi)mentioning
confidence: 99%
“…These scanners offer even better sensitivity than 'normal' (human) ring scanners, but at the cost of a still smaller field of view (typically ∼100 mm diameter), restricting yet further the size of the system that can be investigated. At the University of Tennessee, PEPT experiments have been conducted [19,46,47] using such scanners, including a Concorde Microsystems microPET P4 [48] and a Siemens Inveon [49]; a newer scanner, the Mediso MultiScan LFER [50], is now being explored for PEPT deployment at Virginia Commonwealth University. This scanner is designed for primate imaging, and as such offers a slightly larger field of view than other animal scanners.…”
Section: Conventional Detector Systems (Ring and Planar Scannersmentioning
confidence: 99%
See 1 more Smart Citation
“…Uncertainties are taken to be the standard deviations of the mean in each spatial direction of each of the detected particle images as described in [ 25 ]. This uncertainty estimate is purely statistical and does not distinguish between measurement uncertainty and uncertainty due to tracer movement, nor does it reflect any biases associated with the measurement itself.…”
Section: Methodsmentioning
confidence: 99%
“…To achieve single-cell sensitivity with PET, a novel tracking method was recently developed [20]. This method builds on a previous technique, known as positron emission particle tracking (PEPT), used primarily for measuring liquid and particulate flows in opaque industrial systems [2125]. Unlike conventional PET, PEPT uses list-mode data to directly localise discrete sources, without the intermediate step of reconstructing the image.…”
Section: Introductionmentioning
confidence: 99%