2001
DOI: 10.4028/www.scientific.net/msf.363-365.287
|View full text |Cite
|
Sign up to set email alerts
|

Positronium Fractions and Cavity Sizes Derived from 1- and 2-Detector Doppler Broadening Spectra Positronium Fractions and Cavity Sizes Derived from 1- and 2-Detector Doppler Broadening Spectra

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2002
2002
2015
2015

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…It is possible to obtain the p-Ps intensity by utilizing a multi-Gaussian fitting [17][18][19] of Doppler broadening spectrum using the ACARFIT program included in the PATFIT package. 7 In order to check the reliability of multi-Gaussian fitting to obtain p-Ps intensity, we measured a series of polymer samples using both CDB and conventional positron lifetime measurements.…”
Section: Coincidence Doppler Broadening Measurementsmentioning
confidence: 99%
“…It is possible to obtain the p-Ps intensity by utilizing a multi-Gaussian fitting [17][18][19] of Doppler broadening spectrum using the ACARFIT program included in the PATFIT package. 7 In order to check the reliability of multi-Gaussian fitting to obtain p-Ps intensity, we measured a series of polymer samples using both CDB and conventional positron lifetime measurements.…”
Section: Coincidence Doppler Broadening Measurementsmentioning
confidence: 99%
“…The determination of this factor depends on the measurement of a sample with 100% o-Ps selfannihilation as presented in [15] but for our qualitative disccusion we will omit this. As a first approximation we assume that the pick-off process is described with the same S and W parameters as the bulk annihilation [16]. Then, the experimental results can be interpreted in terms of a and b fractions (see Table 2).…”
Section: Resultsmentioning
confidence: 99%
“…However, these effects are smaller than for the case of direct positron annihilation. The Doppler broadening and angular correlation of the radiation produced by annihilation of p-Ps can provide information on the size and shape of voids in materials. , The total spin angular momentum of o-Ps is equal to one and in vacuum conservation of spin angular momentum makes annihilation of o-Ps into three γ-quanta the only possible decay channel. In a vacuum, this process occurs with a lifetime of 142 ns.…”
Section: Introductionmentioning
confidence: 99%