2016
DOI: 10.1007/s10337-016-3127-8
|View full text |Cite
|
Sign up to set email alerts
|

Possibilities and Limitations of Computer-Assisted Method Development in HILIC: A Case Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
4
2
2

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…. was applied : w=4·t0N gradient ·1+k elut ·f,where N gradient represents the plate number corrected for the retention factor at the moment of elution ( k elution ) : N gradient =N observed ·()1+k elution 2()1+k observed 2,where N observed and k observed are plate number and retention factor values that can be obtained directly from a chromatogram recorded in gradient mode . The corresponding value for N gradient was determined from the scouting runs to be 1100.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…. was applied : w=4·t0N gradient ·1+k elut ·f,where N gradient represents the plate number corrected for the retention factor at the moment of elution ( k elution ) : N gradient =N observed ·()1+k elution 2()1+k observed 2,where N observed and k observed are plate number and retention factor values that can be obtained directly from a chromatogram recorded in gradient mode . The corresponding value for N gradient was determined from the scouting runs to be 1100.…”
Section: Resultsmentioning
confidence: 99%
“…In the last part of the study, we employed the validated two‐parameter retention modeling to optimize the separation of a biotechnological fermentation sample. To this end, we complemented the retention modeling with peak width predictions to predict the chromatographic resolution, using a previously published approach .…”
Section: Introductionmentioning
confidence: 99%
“…These strategies have been developed over the years with increasing knowledge of the parameters influencing retention. An example of this is the development of the Drylab, ChromSword, and PEWS 2 method development software [18,19,42,69–71]. Many of these papers are limited to RPLC, but there are three software packages that can be used for liquid chromatography in general.…”
Section: Methodsmentioning
confidence: 99%
“…New pharmaceutical and biomedical modalities are generating increasingly complex multicomponent mixtures of closely related compounds at a higher throughput. In many cases, it is extremely difficult to optimize the separation by a traditional manual intervention. In this regard, computer-assisted chromatographic modeling has recently become a powerful labor-saving analytical tool to streamline the development of robust and reliable separation methods in both academic and industrial sectors. In this approach, a multifactorial experimental design (temperature, mobile gradient, buffer concentration, etc.) is typically conducted, with the results being input into a software (ACD Laboratories/LC Simulator, DryLabs, etc.)…”
mentioning