2021
DOI: 10.3390/en14185984
|View full text |Cite
|
Sign up to set email alerts
|

Possibilities of Upgrading Warsaw Existing Residential Area to Status of Positive Energy Districts

Abstract: This paper analyses possibilities of refurbishment of Warsaw’s residential buildings towards standards of the Positive Energy District. The annual final energy consumption in the city in 2019 for the district heating was 8668 GWh, gas (pipelines) was 5300 GWh, electricity from the grid was 7500 GWh, while the emission of the carbon dioxide was 5.62 × 109 kg. The city consists of 18 districts, which are heterogeneous in terms of typology and structure of buildings. The great variety of buildings can be seen, fo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
5
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 1 publication
(2 reference statements)
0
5
1
Order By: Relevance
“…The same can be said about the number of building users per unit area or volume: n inh (A net ) and n inh (A usable ) and about ventilation airflow rate: V vent (V H ), V vent (A net ), V vent (A usable ) and V vent (n inh ). Several authors have reported a general trend that older buildings in Poland are more energy-intensive [7,70,73]. However, this relationship was not noticed here, probably due to the fact that some of them could be partly modernised before preparation of energy audits.…”
Section: Buildings Before Planned Modernisationscontrasting
confidence: 53%
See 1 more Smart Citation
“…The same can be said about the number of building users per unit area or volume: n inh (A net ) and n inh (A usable ) and about ventilation airflow rate: V vent (V H ), V vent (A net ), V vent (A usable ) and V vent (n inh ). Several authors have reported a general trend that older buildings in Poland are more energy-intensive [7,70,73]. However, this relationship was not noticed here, probably due to the fact that some of them could be partly modernised before preparation of energy audits.…”
Section: Buildings Before Planned Modernisationscontrasting
confidence: 53%
“…Then, 28 pairs with strong correlation, i.e., when |r| > 0.7 (Table 3), were highlighted with the colour. As can be noticed, energy performance of buildings, described by the E A indicator, varied significantly, from energy efficient (with E A < 65 kWh/m 2 ) to very inefficient buildings with E A > 200 kWh/m 2 [69][70][71]. Total efficiency of the heating system was from 0.64 to 0.96.…”
Section: Buildings Before Planned Modernisationsmentioning
confidence: 98%
“…This Editorial article provides a summary of the Special Issue of Energies, covering the published papers [1][2][3][4][5][6][7][8] which address several of the topics mentioned in the Introduction. Table 1 identifies the most relevant topics in each published paper.…”
Section: Published Papers Highlightsmentioning
confidence: 99%
“…In [6], Hanna Jędrzejuk and Dorota Chwieduk analyze the possibilities for the refurbishment of Warsaw's residential buildings towards the standards of a Positive Energy District. The paper refers to the theoretical potential for the use of renewable energies, which appears to be a rational solution only if there is a reduction in energy demand for traditional methods which, in this case, means reducing the energy demand of existing buildings or erecting new ones in accordance with the latest energy and environmental standards.…”
Section: Published Papers Highlightsmentioning
confidence: 99%
“…Even though different studies and practical experiences of PEDs focus on new development districts, in order to achieve Greenhouse Gasses (GHG) emissions reduction goals by 2050 [24][25][26], it is necessary and urgent to undertake an ambitious transformation process of the existing districts in a sustainable and climate-neutral direction [27][28][29][30]. Today, 75% of buildings in Europe are inefficient from the energy perspective, and their annual retrofitting rate is estimated to be around 1% [8].…”
mentioning
confidence: 99%