2019
DOI: 10.1097/ijg.0000000000001351
|View full text |Cite
|
Sign up to set email alerts
|

Possible Intraluminal Obstruction of the XEN45 Gel Stent Observed With Anterior Segment Optical Coherence Tomography

Abstract: Purpose: We herein describe possible intraluminal obstruction because of a hyperreflective material found in anterior segment optical coherence tomography (AS-OCT) in 16 of 46 cases with XEN45 gel stent. Materials and Methods: This is a retrospective case series of 46 eyes of 39 patients with noncomplicated XEN45 gel stent surgery, analyzed with AS-OCT and slit-lamp photography after at least 6 postoperative months. Res… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
11
2

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(15 citation statements)
references
References 11 publications
2
11
2
Order By: Relevance
“…Intraluminal debris that is difficult to see with the slit-lamp has been documented in the XEN-45 gel stent with AS-OCT, which correlates well with our clinical findings. 13 …”
Section: Discussionmentioning
confidence: 99%
“…Intraluminal debris that is difficult to see with the slit-lamp has been documented in the XEN-45 gel stent with AS-OCT, which correlates well with our clinical findings. 13 …”
Section: Discussionmentioning
confidence: 99%
“…Rigo 58 reported the OCT findings of 46 eyes (39 patients) retrospectively evaluated 6 months or more after an uneventful Xen. Possible intraluminal obstructions evidenced by hyper-reflective material on OCT were identified in 16 eyes (15 POAG eyes and 1 PXG) with unremarkable slit-lamp exams in.…”
Section: Intraluminal Obstructionmentioning
confidence: 99%
“…26 We hypothesize that phacoemulsification-derived particles may enhance bleb inflammation and scarring, as described in other filtering procedures. 27 Additionally, intraluminal organic material obstructing glaucoma implants has been found in combined Phaco-Express P50 procedures in which SBR was unsuccessful. 26 Anterior segment optical coherence tomography has illustrated similar intraluminal obstruction in cases with prior combined phaco-XEN surgery and signs of a flat, nonfunctional bleb.…”
Section: Discussionmentioning
confidence: 99%
“…26 Anterior segment optical coherence tomography has illustrated similar intraluminal obstruction in cases with prior combined phaco-XEN surgery and signs of a flat, nonfunctional bleb. 27 Further studies including systematic anterior segment bleb and stent imaging are needed to validate these hypotheses.…”
Section: Discussionmentioning
confidence: 99%