2019
DOI: 10.1007/s00405-019-05285-z
|View full text |Cite
|
Sign up to set email alerts
|

Post-contrast 3D-FLAIR in idiopathic sudden sensorineural hearing loss

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
11
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 26 publications
1
11
0
1
Order By: Relevance
“…One study reported a correlation between increased signal in the diseased ear and poorer prognosis, but the association was only observed for pre-contrast imaging ( 44 ). Another study described a poorer prognosis when increased signal was observed on MRI performed 4 h after contrast administration ( 69 ). A third study reported a correlation between enhancement seen on MRI taken shortly after contrast injection and poorer initial hearing level but did not find a correlation with prognosis for hearing recovery ( 54 ).…”
Section: Resultsmentioning
confidence: 99%
“…One study reported a correlation between increased signal in the diseased ear and poorer prognosis, but the association was only observed for pre-contrast imaging ( 44 ). Another study described a poorer prognosis when increased signal was observed on MRI performed 4 h after contrast administration ( 69 ). A third study reported a correlation between enhancement seen on MRI taken shortly after contrast injection and poorer initial hearing level but did not find a correlation with prognosis for hearing recovery ( 54 ).…”
Section: Resultsmentioning
confidence: 99%
“…Meanwhile, post-contrast 3D FLAIR MRI findings showed high sensitivity and encouraging prognostic value in several studies. 20,21) An enhancement in the post-contrast 3D FLAIR MRI can demonstrate loosening of the BLB. Although both pre-contrast 3D FLAIR MRI and post-contrast 3D FLAIR MRI can reflect on the integrity of BLB, care should be taken to differentiate between them since the visualized pathology is different.…”
Section: Discussionmentioning
confidence: 99%
“…However, three-dimensional-FLAIR still has the advantage of superior sensitivity for detecting low Gd concentrations in CSF over T1-weighted imaging. 46,89,90 Fast Scan Techniques Several efforts have been made to reduce scan time. Singleshot echo planar imaging-based two-dimensional-FLAIR reduces the scan time.…”
Section: Meningeal Lymphatic Vessel Enhancement Andmentioning
confidence: 99%
“…The comparison of sensitivity regarding low Gd concentration between two‐dimensional and three‐dimensional has not been explored. However, three‐dimensional‐FLAIR still has the advantage of superior sensitivity for detecting low Gd concentrations in CSF over T1‐weighted imaging 46,89,90 …”
Section: Relationship Between Flair and Gd Concentration: Physics And...mentioning
confidence: 99%