2013 IEEE Energy Conversion Congress and Exposition 2013
DOI: 10.1109/ecce.2013.6646832
|View full text |Cite
|
Sign up to set email alerts
|

Post-fault operation of an asymmetrical six-phase induction machine with single and two isolated neutral points

Abstract: -

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
26
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(28 citation statements)
references
References 26 publications
0
26
0
2
Order By: Relevance
“…As the stator d1-q1 current components are required for the flux/torque control in the NP-FSPM motor, another three pairs of stator harmonic current components (the third, the fifth and the seventh), regarded as additional degree of freedom (ADF), can be effectively utilized for an appropriate post-fault operating strategy. It should be noted that the ADFs have been used to deal with open-circuit fault in multiphase machines for various specific aims, such as minimum loss or maximum torque output [21][22][23]. However, there is no evidence that fault-tolerant controllability has ever been attempted before by dispensing with these additional degrees of freedom.…”
Section: Reconstruction Of Harmonic Current Components During Post-famentioning
confidence: 99%
“…As the stator d1-q1 current components are required for the flux/torque control in the NP-FSPM motor, another three pairs of stator harmonic current components (the third, the fifth and the seventh), regarded as additional degree of freedom (ADF), can be effectively utilized for an appropriate post-fault operating strategy. It should be noted that the ADFs have been used to deal with open-circuit fault in multiphase machines for various specific aims, such as minimum loss or maximum torque output [21][22][23]. However, there is no evidence that fault-tolerant controllability has ever been attempted before by dispensing with these additional degrees of freedom.…”
Section: Reconstruction Of Harmonic Current Components During Post-famentioning
confidence: 99%
“…For this reason, the topology shown in Fig. 1, whose post-fault operation under open-phase faults has been already validated [20], has been selected in this work. This topology is formed by an asymmetrical six-phase IM fed by two voltage source converters (VSCs) that are connected to a single dc-link.…”
Section: A Topology Descriptionmentioning
confidence: 99%
“…The fault management in a drive can be classified in three stages: fault detection FD [13][14][15][16][17], fault isolation FI [18][19] and implementation of a fault tolerant control (FTC) [20][21][22][23][24][25]. The implementation of these three stages in the system is necessary to ensure a suitable operation and to protect the system in post-fault situation.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, the most popular configurations are the symmetrical type (S6) and the asymmetrical type with a spatial displacement of 30º (A6) [18]. In addition the three kind of machines can be configured either with single or two neutrals points [6].…”
Section: Introductionmentioning
confidence: 99%
“…Apart from the well-known fault tolerant capability [6][7][8][9][10], some other innovative uses of the additional degrees of freedom have appeared in recent times [11][12][13].…”
Section: Introductionmentioning
confidence: 99%