1990
DOI: 10.1016/0045-6535(90)90360-6
|View full text |Cite
|
Sign up to set email alerts
|

Post furnace formation of PCDDs and PCDFs in MSWI: Observations in an incinerator installed with quench reactor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

1994
1994
2008
2008

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 3 publications
0
5
0
Order By: Relevance
“…Major PCDD products of CuC12-catalyzed condensation of 2,6 chlorinated phenols are as follows: 1,2,3,4,6,8-H, CDD,1,2,4,6,1,2,4,7,1,2,3,6,2,3,7,and 1,3,6,3,7,. These same congeners have been identified as major PCDD products at several municipal waste incinerators where full PCDD distributions have been measured (Ballschmiter and Swerev, 1987;Yamamoto and Inoue, 1990;Weber and Hagenmaier, 1999). In work presented elsewhere (Mulholland et al, 2001b), major P C D D products derived from experiments using a typical distribution of the ten most abundant chlorinated phenols found in municipal waste incinerator emissions are shown to consist largely of those derived from the three 2,4,6 chlorinated phenols.…”
Section: Pcdd Product Ratiosmentioning
confidence: 79%
See 1 more Smart Citation
“…Major PCDD products of CuC12-catalyzed condensation of 2,6 chlorinated phenols are as follows: 1,2,3,4,6,8-H, CDD,1,2,4,6,1,2,4,7,1,2,3,6,2,3,7,and 1,3,6,3,7,. These same congeners have been identified as major PCDD products at several municipal waste incinerators where full PCDD distributions have been measured (Ballschmiter and Swerev, 1987;Yamamoto and Inoue, 1990;Weber and Hagenmaier, 1999). In work presented elsewhere (Mulholland et al, 2001b), major P C D D products derived from experiments using a typical distribution of the ten most abundant chlorinated phenols found in municipal waste incinerator emissions are shown to consist largely of those derived from the three 2,4,6 chlorinated phenols.…”
Section: Pcdd Product Ratiosmentioning
confidence: 79%
“…Regarding the former, Ballschmiter et al (1987 and1988) and Yamamoto et al (1989 and1990) reported that the major chlorinated phenols found in municipal waste incinerators are the congeners with ortho and para sites (2,4,6 carbons) chlorinated. There are three of these: 2,4,6-trichlorophenol (2,4,6-T3CP), 2,3,4,6-tetrachlorophenol (2,3,4,6-T4CP) and pentachlorophenol (PCP).…”
Section: Introductionmentioning
confidence: 99%
“…Samples B and D were collected from a boiler in which circulated fluidized bed (CFB) incineration technology was used. The boiler had an ESP operating at temperatures higher than 300"C, which, according to previous reports [19], caused the formation of PCDDsIPCDFs. In addition, burning in this particular boiler was incomplete.…”
Section: Boiler Characteristics and Chemical Analyses Of Fly Ashmentioning
confidence: 87%
“…This is compounded by the fact that operating temperatures are typically within that required for dioxin formation (250-400°C). Thus in one study [89] 200 ng TEQ/m3 of dioxin at the input to the ESP became 17000ng TEQ/m3 in the stack gas. Therefore temperature control of these components is important.…”
Section: Reducing Exhaust Gas Particle Loadmentioning
confidence: 99%
“…The influence of ESP operational temperature is shown by a tenfold reduction in stack dioxin when moving from 300°C to 200°C [76]. Another study [89] suggested that net dioxin removal can only be achieved by a combination of quenching and calcium sorbent injection. Cooling can be achieved by quenching the exhaust gases but is often effected by the insertion of an additional gas cleaning device in series prior to the ESP or FF.…”
Section: Reducing the Residence Time Of The Flue Gas Between 250 And mentioning
confidence: 99%