2011
DOI: 10.4209/aaqr.2011.05.0055
|View full text |Cite
|
Sign up to set email alerts
|

Post-processing Method to Reduce Noise while Preserving High Time Resolution in Aethalometer Real-time Black Carbon Data

Abstract: Real-time aerosol black carbon (BC) data, presented at time resolutions on the order of seconds to minutes, is desirable in field and source characterization studies measuring rapidly varying concentrations of BC. The Optimized Noisereduction Averaging (ONA) algorithm has been developed to post-process data from the Aethalometer, one of the widely used real-time BC instruments. The ONA program conducts adaptive time-averaging of the BC data, with the incremental light attenuation (∆ATN) through the instrument'… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
132
1
1

Year Published

2013
2013
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 210 publications
(134 citation statements)
references
References 17 publications
0
132
1
1
Order By: Relevance
“…Measuring BC with the micro-aethalometer at one second time resolution is challenging due to the occurrence of signal noise, especially at low concentrations. Therefore, a noise reduction algorithm was used (Hagler et al, 2011) (see Section 2.3).…”
Section: Mobile Monitoring Campaignmentioning
confidence: 99%
See 1 more Smart Citation
“…Measuring BC with the micro-aethalometer at one second time resolution is challenging due to the occurrence of signal noise, especially at low concentrations. Therefore, a noise reduction algorithm was used (Hagler et al, 2011) (see Section 2.3).…”
Section: Mobile Monitoring Campaignmentioning
confidence: 99%
“…The microaethalometer measurements were compared between the different instruments, and also to the measurements of the MAAP instrument at the monitoring station. Noise reduction was realised using the Optimized Noise-reduction Averaging algorithm (ONA algorithm from Hagler et al, 2011), with an attenuation threshold of 0.05. Rescaling parameters were derived from the comparison of the individual micro-aethalometers with the MAAP instrument from the monitoring station.…”
Section: Data Validation and Quality Controlmentioning
confidence: 99%
“…Carbonaceous matter has been found to be associated with human health and urban environmental problems (von Schneidemesser et al, 2010;Hagler et al, 2011;Pavese et al, 2012;Zhou et al, 2012). It (total carbon: TC) consists of two major components: elemental carbon (EC) and organic carbon (OC).…”
Section: Introductionmentioning
confidence: 99%
“…Measuring BC with the micro-aethalometer at one second time resolution is challenging due to the occurrence of signal noise, especially at low concentrations. Therefore, a noise reduction algorithm, the Optimized Noise-reduction Averaging algorithm (ONA algorithm from Hagler et al, 2011), was used with an attenuation threshold of 0.05.…”
Section: Quality Control and Processing Of The Bc Datamentioning
confidence: 99%