Potential of atmospheric pressure ionization sources for the analysis of free fatty acids in clinical and biological samples by gas chromatography-mass spectrometry

Abstract: Because of the central role of fatty acids in biological systems, their accurate quantification is still important. However, the impact of the complex matrix of biologically and clinically relevant samples such as plasma, serum, or cells makes the analysis still challenging, especially, when free non-esterified fatty acids have to be quantified. Here we developed and characterized a novel GC–MS method using pentafluorobenzyl bromide as a derivatization agent and compared different ionization techniques such as… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(14 citation statements)
references
References 58 publications
0
13
1
Order By: Relevance
“…The LOD and LOQ values are in the range of 0.1–1 μM for the intact FA ion and around 10 μM for the regiospecific in-source fragment ions (Table ). This is slightly higher compared to results obtained previously using a triple quadrupole mass spectrometer in pseudo-MRM mode . The reason for this is due to the loss of intensity for the characteristic [FA-PFB] − ion and the difference in the mass analyzer; however, the linearity is not affected.…”
Section: Resultscontrasting
confidence: 60%
See 4 more Smart Citations
“…The LOD and LOQ values are in the range of 0.1–1 μM for the intact FA ion and around 10 μM for the regiospecific in-source fragment ions (Table ). This is slightly higher compared to results obtained previously using a triple quadrupole mass spectrometer in pseudo-MRM mode . The reason for this is due to the loss of intensity for the characteristic [FA-PFB] − ion and the difference in the mass analyzer; however, the linearity is not affected.…”
Section: Resultscontrasting
confidence: 60%
“…Both have also been reported in cuttlefish and tuna. , Moreover, quantification can be done using the [FA-PFB] − ion for FAs that are not included as standards in the calibration curve. Here similar FAs can be used for quantification as the response for many FAs is rather similar when ionized by APCI in negative mode …”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations