2013
DOI: 10.1007/s10967-013-2473-3
|View full text |Cite
|
Sign up to set email alerts
|

Potential use of the activation energy value calculated from the thermoluminescence glow curves to detect irradiated food

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
8
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 13 publications
1
8
0
Order By: Relevance
“…The TL value at each temperature is found to increase with increasing absorbed dose in the product. The maximum TL values for each dose were observed at 200 • C. As observed, the main differences between irradiated and non-irradiated samples are based on (i) the intensity and (ii) the shape of the glow emission [8]. The obtained ratio among the TL intensities of the samples allows us to discriminate irradiated from non-irradiated samples, even after longer periods of time (up to 1 month), which is one order of magnitude less than the maximum recommended by the committee of experts from the FAO/WHO/IAEA [12] for conservation of herbs, spices, or seasonings.…”
Section: Resultssupporting
confidence: 59%
See 3 more Smart Citations
“…The TL value at each temperature is found to increase with increasing absorbed dose in the product. The maximum TL values for each dose were observed at 200 • C. As observed, the main differences between irradiated and non-irradiated samples are based on (i) the intensity and (ii) the shape of the glow emission [8]. The obtained ratio among the TL intensities of the samples allows us to discriminate irradiated from non-irradiated samples, even after longer periods of time (up to 1 month), which is one order of magnitude less than the maximum recommended by the committee of experts from the FAO/WHO/IAEA [12] for conservation of herbs, spices, or seasonings.…”
Section: Resultssupporting
confidence: 59%
“…The calculation of the value of E using the IR method can be considered as a reasonably good estimation, although they can vary according to the preheating temperature [8]. Compared to the detection of food irradiation based on the normal glow ratios in [9,14,15], to ensure the IR method has fewer errors, the correlation coefficient (r 2 ) must be at least 0.999 to identify the irradiated foods.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Such values of trap depth parameters indicate the lifetime of electron in these traps. Approximately, the E value of the TL chilli powder sample irradiated with 4 kGy was determined to have a greater value than the others [13]. The values of s of chilli powder samples irradiated with 0, 4 and 8 kGy according to GCD method of the three TL glow peak were also determined as 1.56 x 10 9 , 0.15 x 10 11 , 0.39 x 10 10 (stored 360 h) and 2.8 x 10 9 , 4.22 x 10 11 , 1.04 x 10 10 (stored 720 h).…”
Section: Resultsmentioning
confidence: 97%