2008
DOI: 10.1016/j.talanta.2007.12.023
|View full text |Cite
|
Sign up to set email alerts
|

Potentiometric measurement of ascorbate by using a solvent polymeric membrane electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
16
0

Year Published

2009
2009
2013
2013

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 18 publications
(17 citation statements)
references
References 32 publications
1
16
0
Order By: Relevance
“…Direct evidence of permanganate fluxes across ISE membrane has been tracked by graphite stove atomic absorption spectroscopy [18]. In the present work, the amounts of released permanganate ions are modulated by applying external currents.…”
Section: Current-controlled Release Of Permanganate Ions At Membrane mentioning
confidence: 80%
See 2 more Smart Citations
“…Direct evidence of permanganate fluxes across ISE membrane has been tracked by graphite stove atomic absorption spectroscopy [18]. In the present work, the amounts of released permanganate ions are modulated by applying external currents.…”
Section: Current-controlled Release Of Permanganate Ions At Membrane mentioning
confidence: 80%
“…fluxes in the direction of the sample solution) has been developed for measuring a wide range of analytes which can decrease the concentrations of the indicator ions released at the samplemembrane phase boundary via complexing [17], redox [18] or enzyme-catalyzed reactions [19][20][21]. Such an ISE membrane not only serves as a polymer matrix for reagent release, but also works as a transducer for sensitive potentiometric detection, making the ISE membrane very attractive for sensor miniaturization.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The conventional heparin selective membranes contained 1.5 wt% TDMAC, 66 wt% PVC and 32.5 wt% DOS (membrane 3). Membranes were prepared as described before [8]. For all the measurements, 50 mmol/L Tris-HCl buffer containing 0.12 mol/L NaCl was used as sample background and inner filling solution.…”
Section: Methodsmentioning
confidence: 99%
“…The same group also developed an anion electrode based on precipitate equilibrium at the sample-membrane phase boundary with released silver ions from the sensing membrane [19]. Our group has shown that the outward ion fluxes of ISE membrane can be used as a reagent controlled-release approach for redox sensing chemistries with submicromolar lower detection limits [20]. Such ISE membrane not only serves as a polymer matrix for reagent release, but also works as a transducer for sensitive potentiometric detection.…”
Section: Introductionmentioning
confidence: 99%