Power compensators based on magnetically controlled shunt reactors in electric networks with a voltage between 110 kV and 500 kV

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
8
0
3

Year Published

2014
2014
2021
2021

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(11 citation statements)
references
References 0 publications
0
8
0
3
Order By: Relevance
“…It is repeatedly shown [1,5,6,8], that implementation of controlled shunt compensation devices at 500 kV long-distance transmission systems does not much influence on mutual angles between generators and transient stability, since such an interaction is defined on excitation and active power control systems of generators themselves. But voltage behavior at intermediate points of transmission systems depends primarily on performance of shunt compensation device, especially in post-fault operations.…”
Section: Application Of Controlled Shunt Reactors In Oil-productimentioning
confidence: 99%
See 1 more Smart Citation
“…It is repeatedly shown [1,5,6,8], that implementation of controlled shunt compensation devices at 500 kV long-distance transmission systems does not much influence on mutual angles between generators and transient stability, since such an interaction is defined on excitation and active power control systems of generators themselves. But voltage behavior at intermediate points of transmission systems depends primarily on performance of shunt compensation device, especially in post-fault operations.…”
Section: Application Of Controlled Shunt Reactors In Oil-productimentioning
confidence: 99%
“…Currently, more than 8 GVA of total reactor capacity have been installed around world in various voltage buses, from 10 to 500 kV [8].…”
Section: Introductionmentioning
confidence: 99%
“…And MCR is a new type SVC of which the working principle is similar to TCR [2] . The reactive power control of the TCR, MCR and STATCOM is stepless adjustable and the response time is as fast as 20ms [3] [4] . However, the advantage of the MCRs over TCRs and STATCOM is that MCRs can be connected directly to the ultra high voltage up to 1000 kV without numerous thyristor valves in series [4] .…”
Section: Introductionmentioning
confidence: 99%
“…Вступ. У даний час виникли об'єктивні передумови для розвитку електроенергетики України ХХІ століття на новій технологічній основі, що характеризує перехід до нового розвитку світової економіки шляхом створення інтелектуальної енергосистеми з активноадаптивною електричною мережею, що побудована на концепції Smart Grid («розумні мережі») [1][2][3][4][5][6]. Розвиток електроенергетики в передових країнах супроводжується інтенсивним пошуком нових технологій для вирішення проблеми подальшого підвищення ефективності роботи магістральних електричних мереж з метою оптимального розподілу потоків потужності об'єднаної енергосистеми.…”
unclassified
“…Наприклад, характерним випадком таких комутацій є добова зміна потужності, за якої частота комутацій ШР призводить до вичерпання ресурсів комутаційної апаратури. За кожної такої операції спрацьовується ресурс вимикачів, а реактор піддається впливу комутаційних перенапруг [1,13] та, як наслідок, ізоляція реактора швидко пошкоджується. Крім того, відключення шунтуючих реакторів небезпечно для всієї електричної мережі, оскільки при раптовому відключенні лінії вимушена складова перенапруг без шунтуючих реакторів виявляється значно вищою гранично допустимої.…”
unclassified